Evaluation of respiratory inductive plethysmography in the measurement of breathing pattern and PEEP-induced changes in lung volume.
- P Valta, J Takala, R Foster, C Weissman, and J M Kinney.
- Department of Intensive Care, Kuopio University Hospital, Finland.
- Chest. 1992 Jul 1;102(1):234-8.
Study ObjectiveTo assess the accuracy of the respiratory inductive plethysmography in the measurement of PEEP-induced changes in end-expiratory lung volume during mechanical ventilation and its accuracy and stability in the measurement of ventilation during controlled mechanical ventilation and spontaneous breathing.DesignAn open comparison between two methods using a criterion standard. Either a pneumotachometer (mechanically ventilated patients) or a spirometer (spontaneously breathing subjects) was used as the reference method.SettingTertiary care center; a multidisciplinary intensive care unit and a metabolic research unit.PatientsSix mechanically ventilated, paralyzed postoperative open heart surgery patients, six spontaneously breathing COPD patients, and eight healthy volunteers.InterventionsStepwise increases and reductions of PEEP from zero to 12 cm H2O during controlled mechanical ventilation; repeated validation of the calibration of the respiratory inductive plethysmography (RIP) in both mechanically ventilated and spontaneously breathing subjects.Measurements And ResultsThe baseline drift of the RIP in vitro was 10 ml/150 min and in a ventilated model it was 20 ml/150 min. In mechanically ventilated patients, the mean error of the calibration after 150 min was within +/- 5 percent. Change in end-expiratory lung volume (EELV) during the stepwise increase of PEEP up to 12 cm H2O was 849 +/- 136 ml with the RIP and 809 +/- 125 ml with the pneumotachometer (PT), and during the stepwise reduction of PEEP it was 845 +/- 124 ml and 922 +/- 122, respectively (not significant [NS]. The mean difference between methods in the measurement of change in EELV was -6.6 +/- 3.5 percent during increasing and 6.6 +/- 6.7 percent during decreasing PEEP (NS). Both in mechanically ventilated and spontaneously breathing subjects, the difference between methods was significant for VT and VT/TI. The difference in VT was -2.2 +/- 0.2 percent during mechanical ventilation, -1.1 +/- 0.5 percent in spontaneously breathing COPD patients, and 2.9 +/- 0.4 percent in healthy volunteers (NS between groups).ConclusionsThe RIP is sufficiently accurate for the measurement of PEEP-induced changes in EELV during controlled mechanical ventilation. The accuracy of tidal volume measurement is similar during mechanical ventilation and spontaneous breathing. The calibration of the RIP is stable enough for bedside monitoring of changes in lung volumes.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.