• Anesthesia and analgesia · May 2004

    The relationship between bispectral index and electroencephalographic parameters during isoflurane anesthesia.

    • Yasuhiro Morimoto, Satoshi Hagihira, Yumika Koizumi, Kazuyoshi Ishida, Mishiya Matsumoto, and Takefumi Sakabe.
    • Department of Anesthesiology-Resuscitology, Yamaguchi University School of Medicine, Minami-Kogushi Ube, Yamaguchi, 755-8505, Japan. naa01346@nifty.ne.jp
    • Anesth. Analg. 2004 May 1; 98 (5): 1336-40, table of contents.

    UnlabelledBispectral index (BIS) integrates various electroencephalographic (EEG) parameters into a single variable. However, the exact algorithm used to synthesize the parameters to BIS values is not known. The relationship between BIS and EEG parameters was evaluated during nitrous oxide/isoflurane anesthesia. Twenty patients scheduled for elective ophthalmic surgery were enrolled in the study. After EEG recording with a BIS monitor (A-1050) was begun, general anesthesia was induced and maintained with 0.5%-2% isoflurane and 66% nitrous oxide. Using software we developed, we continuously recorded BIS, spectral edge frequency 95% (SEF95), and EEG parameters such as relative beta ratio (BetaRatio), relative synchrony of fast and slow wave (SynchFastSlow), and burst suppression ratio. BetaRatio was linearly correlated with BIS (r = 0.90; P < 0.01; n = 253) at BIS more than 60. At a BIS range of 30 to 80, SynchFastSlow (r = 0.60; P < 0.01; n = 3314) and SEF95 (r = 0.75; P < 0.01; n = 3339) were linearly correlated with BIS. The correlation between BIS and SEF95 was significantly better than the correlation between BIS and SynchFastSlow (P < 0.01). At BIS less than 30, the burst suppression ratio was inversely linearly correlated with BIS (r = 0.76; P < 0.01; n = 65). At BIS less than 80, burst-compensated SEF95 was linearly correlated with BIS (r = 0.78; P < 0.01; n = 3404). In the range of BIS from 60 to 100, BIS can be calculated from BetaRatio. At surgical levels of anesthesia, BIS and SynchFastSlow (a parameter derived from bispectral analysis) or burst-compensated SEF95 (derived from power spectral analysis) are well correlated. However, our results show that SynchFastSlow has no advantage over SEF95 in calculation of BIS.ImplicationsThe relationship between bispectral index (BIS) and electroencephalographic parameters was evaluated during nitrous oxide/isoflurane anesthesia. At surgical levels of anesthesia, BIS and the relative synchrony of fast and slow wave (a parameter derived from bispectral analysis) or burst-compensated spectral edge frequency 95% (a parameter derived from power spectral analysis) are well correlated.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.