Acta neurochirurgica · Jan 2009
Risk factors for complications during intracranial electrode recording in presurgical evaluation of drug resistant partial epilepsy.
- Chong H Wong, Julie Birkett, Karen Byth, Mark Dexter, Ernest Somerville, Deepak Gill, Ray Chaseling, Michael Fearnside, and Andrew Bleasel.
- Westmead Hospital, Darcy Road, Westmead, New South Wales 2145, Australia.
- Acta Neurochir (Wien). 2009 Jan 1;151(1):37-50.
BackgroundIntracranial electrode monitoring is still required in epilepsy surgery; however, it is associated with significant morbidity.ObjectiveTo identify risk factors associated with complications during invasive intracranial EEG monitoring.Materials And MethodsRetrospective study of all patients undergoing invasive monitoring at Westmead between 1988-2004. From detailed chart reviews, the following variables were recorded: duration of intracranial monitoring, the site of grid implantation, number of grids and electrodes, seizure frequency, postoperative complications and seizure outcome.ResultsSeventy-one patients (median age: 24 years) underwent subdural electrode implantation; 62% had extratemporal lobe epilepsy and 46% were non-lesional. Of the 58 monitored patients who had cortical resections, 45 had good seizure outcomes. Complications related to subdural electrode implantation included transient complications requiring no treatment (12.7%), transient complications requiring treatment (9.9%) and two deaths (2.8%). Specific complications included subdural haemorrhage, transient neurological deficit, infarction and osteomyelitis. The two deaths occurred within 48 h of implantation were related to raised intracranial pressure (one venous infarction, one unexplained). Complications were associated with maximal size of grid (p < 0.001), greater number of electrodes (p < 0.001), electrode density per cortical surface implanted (p < 0.001), right central surface implantation (p = 0.003) and left central surface implantation (p = 0.013). Multiple logistic regression identified larger size grids and right central surface implantation as independent predictors of complications.ConclusionThere are significant complications during intracranial EEG evaluations but the majority of these are transient. We found a relationship between the size of the electrode arrays and the incidence of complications. The results of this study have been used to modify our implantation and monitoring protocols.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.