-
Critical care medicine · May 2007
Calculation of intratracheal airway pressure in ventilated neonatal piglets with endotracheal tube leaks.
- Werner Nikischin, Susanne Herber-Jonat, Philipp von Bismarck, Malte Lange, and Ralph Grabitz.
- Department of Pediatrics, Univesity of Kiel, Germany. nikischin@pediatrics.uni-kiel.de
- Crit. Care Med. 2007 May 1;35(5):1383-9.
ObjectiveIn ventilated neonates, only the applied pressure of the ventilator is adjusted and monitored. When an endotracheal tube leaks, intratracheal pressure decreases depending on the size of the endotracheal tube and of the leak. Furthermore, an increase in resistance and/or compliance might delay the increase of intratracheal pressure during inspiration and its decline during expiration. Short inspiratory time can cause insufficient ventilation, because intratracheal pressure peak might not be reached. Short expiratory time may lead to air trapping, because intratracheal pressure could not return to baseline. The aim of this study was to develop a mathematical algorithm to calculate intratracheal pressure continuously during ventilation and to evaluate the accuracy of this method.DesignProspective, animal study.SettingUniversity research laboratory.SubjectsTo verify the mathematical algorithm, eight neonatal piglets (1600-2600 g) were studied under different endotracheal tube leak conditions (45% to 98%). The median compliance and resistance were 1.06 mL/cm H2O/kg and 123 cm H2O/L/sec, respectively.InterventionsPressure decreases caused by the different endotracheal tubes were measured in a model while air flow was increased stepwise. Based on these results, a mathematical method was developed to calculate intratracheal pressure under leak conditions continuously in relation to the flow through the endotracheal tube as well as to calculate the values of resistance, compliance, and applied pressure of the ventilator.Measurements And Main ResultsThe intratracheal pressure calculated was compared with the measured intratracheal pressure over time. The differences between measured and calculated intratracheal pressure related to peak applied pressure of the ventilator did not exceed 10%. The medians of absolute amounts of differences between measured and calculated intratracheal pressure were <1 cm H2O.ConclusionsThe accuracy of the calculation of intratracheal pressure ensures adequate monitoring of artificial ventilation, even in the presence of endotracheal tube leaks. This might decrease the risk of barotrauma and improve the effectiveness of ventilation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.