-
Anesthesia and analgesia · Jan 2003
Comparative StudyA comparison of lactated ringer's solution to hydroxyethyl starch 6% in a model of severe hemorrhagic shock and continuous bleeding in dogs.
- Zeev Friedman, Haim Berkenstadt, Sergei Preisman, and Azriel Perel.
- Department of Anesthesiology and Intensive Care, The Chaim Sheba Medical Center, Tel Hashomer, Israel (affiliated with the Sackler School of Medicine, Tel Aviv University).
- Anesth. Analg. 2003 Jan 1;96(1):39-45, table of contents.
UnlabelledIn this randomized, controlled study in dogs, we examined the short-term effects of blood pressure targeted fluid resuscitation with colloids or crystalloids solutions on systemic oxygen delivery, and lactate blood concentration. Fluid resuscitation using hydroxyethyl starch (HES) 6% to a mean arterial blood pressure (MAP) of 60 mm Hg was compared with lactated Ringer's solution (LR) to a MAP of 60 or 80 mm Hg (LR60 and LR80, respectively). The model was one of withdrawal of blood to a MAP of 40 mm Hg through an arterial catheter that was then connected to a system allowing bleeding to occur throughout the study whenever MAP exceeded 40 mm Hg. Target MAP was maintained for 60 min with a continuous infusion of the designated fluid replacement. All 15 dogs (5 in each group) survived until the last measurement. Blood loss in the LR80 group (2980 +/- 503 mL) (all values mean +/- SD) was larger than in the LR60 and HES60 groups (1800 +/- 389 mL, and 1820 +/- 219 mL, respectively) (P < 0.001). Whereas 840 +/- 219 mL of HES60 was needed to maintain target MAP, 1880 +/- 425 mL of LR was needed in the LR60 group, and 4590 +/- 930 mL in the LR80 group (P < 0.001). Lactate blood concentrations were smaller and delivered O(2) higher in the HES60 group (35 +/- 17 mg/dL and 239 +/- 61 mL/min, respectively) in comparison to the LR60 group (89 +/- 18 mg/dL and 140 +/- 48 mL/min, respectively) and the LR80 group (75 +/- 23 mg/dL and 153 +/- 17 mL/min, respectively) (P = 0.02 and P = 0.026). In conclusion, fluid resuscitation during uncontrolled bleeding, to a target MAP of 60 mm Hg, using HES60 resulted in larger oxygen delivery and smaller systemic lactate A resuscitation to a target MAP of 60 or 80 mm Hg using LR.ImplicationsFluid resuscitation to a target mean arterial blood pressure of 60 mm Hg during uncontrolled bleeding resulted in larger oxygen delivery and smaller systemic lactate concentrations when hydroxyethyl starch 6% was used, in comparison to lactated Ringer's solution resuscitation to a target mean arterial blood pressure of 60 or 80 mm Hg.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.