• J Vet Emerg Crit Care (San Antonio) · Sep 2013

    Comparative Study

    Comparison of invasive versus noninvasive blood pressure measurements before and after hemorrhage in anesthetized greyhounds using the Surgivet V9203.

    • Eleanor A Drynan and Anthea L Raisis.
    • Department of Anaesthesia, School of Veterinary and Biomedical Sciences, Murdoch University, Murdoch, Australia.
    • J Vet Emerg Crit Care (San Antonio). 2013 Sep 1;23(5):523-31.

    ObjectiveTo determine the agreement between blood pressure obtained with a noninvasive technique and direct technique using the Surgivet V9203 at varying blood pressure levels created using a canine hemorrhage model.DesignExperimental study.SettingUniversity Teaching Hospital.AnimalsTwenty-nine greyhounds with an average weight of 30 kg. Approval from the Murdoch University Animal Ethics Committee was obtained (R228609).MethodsArterial blood pressure (BP) was measured noninvasively (NIBP) via a cuff placed over the dorsal metatarsal artery and via a catheter in the contralateral dorsal metatarsal artery (IBP). Retrospectively the blood pressure measurements recorded were divided into various BP categories. A total of 84 paired readings were obtained. The data were further analyzed with respect to heart rate [<120/min and >120/min]. Comparison of the measurements was performed using the Bland-Altman method.ResultsFor all categories, BP measurements were generally lower when recorded using the oscillometric technique [Systolic (Sys) bias 4.20 kPa (31.54 mm Hg), mean bias 0.52 kPa (3.93 mm Hg), and diastolic bias 1.04 kPa (7.83 mm Hg)]. Mean arterial BP had the least bias and greatest precision in the hypotensive group (bias 0.174 kPa (1.3063 mm Hg), precision 0.79 kPa (5.89 mm Hg)), low BP group (bias 0.62 kPa (4.67mm Hg) and precision 0.89 kPa (6.67mm Hg)) and normotensive group [bias 0.76 kPa (5.71 mm Hg) and precision 1.16 kPa (8.73 mmHg)].ConclusionsThe results demonstrate that the agreement between NIBP measurements and IBP, are within the limits of agreement recommended by the American College of Veterinary Internal Medicine Hypertension Consensus Panel for all pressures except Sys BP. This suggests that mean and diastolic NIBP using the Surgivet V9203 are a clinically acceptable alternative of IBP in hypovolemic hypotensive dogs.© Veterinary Emergency and Critical Care Society 2013.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.