• J Spinal Disord Tech · Oct 2014

    Clinical Trial

    Incidence of lumbar spine pedicle breach after percutaneous screw fixation: a radiographic evaluation of 601 screws in 151 patients.

    • Zachary A Smith, Koichi Sugimoto, Cort D Lawton, and Richard G Fessler.
    • Department of Neurological Surgery, Northwestern University, Chicago, IL.
    • J Spinal Disord Tech. 2014 Oct 1;27(7):358-63.

    Study DesignProspective clinical study.ObjectivesAlthough percutaneous pedicle screw fixation continues to be increasingly practiced, there remain few reports specifically addressing the accuracy and clinical safety of this technique. The goal of this study is to evaluate the accuracy of fluoroscopically guided pedicle screw placement in the lumbar spine.Summary Of Background DataPedicle breach rates vary substantially in the literature. Pedicle breach rates have been reported to be as high as 29% with the traditional, open technique. With the use of computer-assisted 2-dimensional fluoroscopy, breach rates have been reported between 5% and 23%. Furthermore, in a series of 225 pedicles instrumented with 3-dimensional fluoroscopy, the reported breach rate was 1.8%.MethodsA total of 151 patients were evaluated after instrumented single-level or 2-level minimally invasive transforaminal lumbar interbody fusion with 601 screws placed for percutaneous fixation. The treated patients had an average age of 56.6 y (20-85 y) and there were 129 cases of single-level and 22 cases of 2-level. The levels of pedicle screw fixation included (level, patient numbers): L1/L2 (1), L2/L3 (2), L3/L4 (33), L4/L5 (101), L5/S1 (46). Radiographic results included postoperative computed tomographic scan. Patients were followed prospectively for potential clinical symptoms.ResultsIn a total of 601 instrumented pedicles, there were 37 pedicle breaches (6.2%). Of these, 22 (3.7%) were significant breaches (≥3 mm). The level of the breached pedicles were L3 (5/46, 10.2%), L4 (12/201, 7.0%), L5 (15/158, 9.5%), S1 (3/47, 3.4%). The side/location of breach was characterized as follows: medial (22), lateral (12), superior (2), and inferior (1). There were 2 symptomatic breaches, both associated with a medial breach at the L5 pedicle. Symptoms from these events were transient and did not require hardware repositioning. There were no other complications.ConclusionsPercutaneous pedicle screw fixation in the lumbar spine continues to be a technique embraced by modern spinal surgeons. The use of intraoperative fluoroscopic guidance is both a clinically safe and accurate method for instrumentation and is of comparable accuracy to other techniques. Although trajectory errors may occur, they are of rare clinical significance.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…