J. Cardiothorac. Vasc. Anesth. · Apr 2003
Comparative StudyMeasurement of cardiac output after cardiac surgery by a new transesophageal Doppler device.
- Philip Jaeggi, Christoph K Hofer, Richard Klaghofer, Patricia Fodor, Michele Genoni, and Andreas Zollinger.
- Institute of Anesthesiology, Triemli City Hospital, Zurich, Switzerland.
- J. Cardiothorac. Vasc. Anesth. 2003 Apr 1;17(2):217-20.
ObjectivesAssessment of hemodynamics by transesophageal Doppler devices (TDD) may be a less invasive alternative to the pulmonary artery catheter. In contrast to the TDD evaluated so far, a new monitor (HemoSonic100) measures both blood flow velocity and the diameter of the descending aorta. The aim of this study was to assess the accuracy of the cardiac output/index (CO/CI) measured by this device compared with the CO/CI measured by thermodilution.DesignProspective nonrandomized study.SettingCommunity hospital; university-based statistician.ParticipantsTwenty-two patients.InterventionsElective coronary artery bypass grafting and/or valve replacement/repair.Measurements And Main ResultsAfter routine cardiac surgery, CO/CI was determined in the intensive care unit by iced-water bolus (IWB), continuous cardiac index (CCI) assessment, and the TDD. Matched measurements were made with each patient at intervals of 30 minutes. Six percent of sets were incomplete because of failed signal detection by the TDD. Bland-Altman analysis revealed a mean bias of 0.23 L/min/m(2) for TDD and IWB. Mean bias for CCI and IWB was 0.11 L/min/m(2). The correlation between TDD and IWB (r(2) = 0.09) for cardiac index was found to be inferior to the correlation between CCI and IWB (r(2) = 0.65). Trend analysis between sequential measurements (T1-4: dTDD, dCCI, dIWB) showed a lower correlation between dTDD and dIWB (r(2) = 0.1) compared with the correlation between dCCI and dIWB (r(2) = 0.44).ConclusionThe transesophageal Doppler device (HemoSonic100) cannot be recommended as a sole method for monitoring cardiac output in patients after cardiac surgery.Copyright 2003 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.