• Surg Technol Int · Sep 2013

    Clinical Trial

    The silicone ring tourniquet in orthopaedic operations of the extremities.

    • Georgios I Drosos, Athanasios Ververidis, Rodion Mavropoulos, Georgios Vastardis, Konstantinos I Tsioros, and Konstantinos Kazakos.
    • Department of Orthopaedic Surgery Medical School, Democritus University of Thrace University General Hospital of Alexandroupolis Alexandroupolis, Greece.
    • Surg Technol Int. 2013 Sep 1;23:251-7.

    AbstractTourniquets provide a bloodless field in limb operations and their introduction in orthopaedic operative technique has been considered as a landmark. A new tourniquet device, a silicone ring tourniquet (SRT) (HemaClear or S-MART, OHK Medical Devices, Haifa, Israel), was introduced into clinical practice a few years ago. A few clinical studies as well as comparative studies in volunteers have reported its use in a relatively small number of cases. The aim of this prospective study is to report the clinical use of this device in a large number of patients, including all possible applications of a tourniquet. The SRT was used in 536 cases including 337 male and 119 female patients with a mean age of 43.7 years (range 6 to 87 years). The average tourniquet time was 58.5 minutes (range 6 to 180 minutes). It was applied in 362 (67.5%) elective and in 174 (32.5%) trauma cases including fractures (n:109, 62.6%) and soft-tissue injuries (n:65, 37.4%). The most frequent application site was the femur (n:255, 47.6%), followed by the forearm (n:154, 28.7%), humerus (n:65, 12.1%), and calf (n:62, 11.6%). Because the device is sterile it was possible to use it in operations in which the pneumatic tourniquet cannot be used, such as open reduction and internal fixation of humeral shaft and femoral supracondylar fractures. In 14 patients (2.6%), the tourniquet failed intraoperatively, and the cause was an unexpected raised blood pressure. The SRT - with a pre-set pressure according to the size and the tension model - is easy to apply. It is sterile, and occupies a narrow area of the limb. Its application combines three functions at the same time: exsanguination, tourniquet, and stockinet application. Although it cannot entirely replace the classic pneumatic tourniquet, it is a safe and useful device in orthopaedic operations because of its advantages.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…