• Am J Emerg Med · Mar 2013

    Comparative Study Clinical Trial

    Pocket mobile smartphone system for the point-of-care submandibular ultrasonography.

    • Jacek Wojtczak and Peter Bonadonna.
    • Department of Anesthesiology, University of Rochester School of Medicine and Dentistry, Rochester, NY 14642, USA. gryf70@yahoo.com
    • Am J Emerg Med. 2013 Mar 1;31(3):573-7.

    BackgroundFocused ultrasonography of the airway may be useful in the prediction of difficult intubation. The wider use of sonography in quantitative airway assessment may depend on the availability of highly portable, inexpensive, and accurate ultrasound systems. Pocket-sized ultrasound devices are emerging as a useful tool for point-of-care ultrasonography. The aim of this study was to evaluate the suprahyoid airway of healthy volunteers using a smartphone-based ultrasound imaging system in comparison with a platform-based machine.MethodsMobisante MobiUS SP1 system with 2 mechanical sector (3.5 and 7.5 MHz) probes was used to acquire images of the tongue and measure the diameter of the hyomental muscle in the mouth floor. In the same group of subjects, imaging and measurements were repeated using BK Medical Flex Focus 400 ultrasound system with linear (18 MHz ) and curved 5 (MHz) transducers. The MobiUS system was also used to image plastic cylinders and procedure needles embedded in tofu bars. Outside diameters of cylinders were measured using digital calipers and sonography.ResultsThe mean diameter of the hyomental muscle in 10 healthy volunteers was 7.22 ± 1.6 mm using BK 18 MHz probe, 7.11 ± 1.7 mm using MobiUS 7.5 MHz probe, and 7.84 ± 2 mm using MobiUS 3.5 MHz probe. These means were not statistically different (BK vs Mo 7.5, P = .74, and BK vs Mo 3.5, P = .13). The mean outside diameter of plastic cylinders measured with digital calipers was 10.1 ± 0.2 mm (n = 5) vs 9.8 ± 0.3 mm and 10.2 ± 0.2 mm using 3.5 and 7.5 MHz probes, respectively. These means were not statistically different (calipers vs Mo 3.5, P = .16 and calipers vs Mo 7.5, P = .39).ConclusionMobisante MobiUS system was able to acquire clinically useful images of the suprahyoid airway and muscular architecture in the mouth floor and allowed accurate measurements of linear distances.Copyright © 2013 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…