Journal of anesthesia · Jan 2009
Randomized Controlled TrialInsertion length and resistance during advancing of epidural catheter.
- Pankaj Kundra, Senthil Kumar Viswanath, Dharam S Meena, and Ashok Badhe.
- Department of Anaesthesiology and Critical Care, Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Pondicherry, India.
- J Anesth. 2009 Jan 1;23(4):494-9.
PurposeThe migration of an epidural catheter into the intravascular and subarachnoid spaces sometimes occurs. This study was designed to investigate where the resistance was felt during the advancing of the catheter into the epidural space and whether the length of catheter advanced in the epidural space affected the incidence of catheter migration.MethodsOne hundred and twenty women, American Society of Anesthesiologists (ASA) 1 or 2, scheduled to undergo lower abdominal surgeries with epidural anesthesia were randomly assigned to two groups according to the length of the epidural catheter advanced; 4 cm (n = 60) or 8 cm (n = 60). The length where resistance to advancing the catheter was perceived was recorded in all patients, and the incidence of aspiration of blood or cerebrospinal fluid (CSF) was obtained. Further, the catheters removed 48 h after surgery were scrutinized for their bending sites.ResultsResistance was felt in 83 (69.2%) patients and the mean length in the epidural space at which resistance was found was 2.5 +/- 1.2 cm. Blood was aspirated in 9 (7.5%) patients when resistance to advancing the catheter was overcome, but CSF was aspirated in no patient. A distal bend was observed 2.4 +/- 1.3 cm from the tip of the catheter, and the sites of bending were correlated with the length where resistance was encountered. An additional proximal bend was observed in 35 (58%) patients in the 8-cm group, and in 2 patients (3%) in the 4-cm group (P < 0.001), probably due to coiling of the catheter.ConclusionAt approximately 2.5 cm in the epidural space, advancing an epidural catheter causes resistance. Further advancing past this point may cause migration of the catheter into the vessels, or the coiling of the catheter.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.