J. Cardiothorac. Vasc. Anesth. · Dec 1994
Comparative StudyComparison of cardiac output measurement by continuous thermodilution with electromagnetometry in adult cardiac surgical patients.
- C W Hogue, M Rosenbloom, C McCawley, and D G Lappas.
- Department of Anesthesiology, Washington University School of Medicine, St. Louis, MO 63110.
- J. Cardiothorac. Vasc. Anesth. 1994 Dec 1;8(6):631-5.
AbstractA pulmonary artery catheter (PAC) capable of continuous cardiac output (CCO) determination by thermodilution has recently been introduced. The purpose of this study was to compare CCO with two other methods of cardiac output (Ot) determination: electromagnetometry (EM) and standard bolus thermodilution cardiac output (BCO). Following median sternotomy and pericardiotomy, an EM ring probe was placed around the ascending aorta in 25 adult cardiac surgical patients and connected to an EM flowmeter interfaced with a calibrated strip recorder. Measurements were obtained over a 15- to 20-minute interval during a period of stable EM-determined Ot prior to initiation of cardiopulmonary bypass and in the absence of surgical stimulation. The CCO system averages Ot over a 3-minute interval, updating the measurement every 30 seconds. Cardiac output determined by the CCO system was compared with EM Ot averaged from the prior 3-minute period and with BCO obtained immediately after changing the Ot monitor from the continuous to bolus mode. Compared with EM, the bias for CCO was -0.48 L/min, precision 0.56 L/min, and the limits of agreement 1.12 L/min. Bias, precision, and limits of agreement of CCO compared with BCO were 0.41, 0.82, 1.64 L/min, respectively. Correlation between EM and CCO was r = 0.80 and between CCO and BCO r = 0.64. Cardiac output determined by CCO was within 10% of the EM determination for 37 measurements, between 10% and 20% for 17, and greater than 20% for 7 measurements.(ABSTRACT TRUNCATED AT 250 WORDS)
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.