-
- Andreas Rothbart, Peng Yu, Lutz Müller-Lobeck, Claudia D Spies, Klaus-Dieter Wernecke, and Irit Nachtigall.
- Department of Anesthesiology and Intensive Care Medicine Campus Charité Mitte and Campus Virchow-Klinikum, Charité-Universitaetsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany. andreas.rothbart@charite.de.
- BMC Res Notes. 2015 Sep 21; 8: 463.
BackgroundVenous access, a prerequisite for anesthesiological and surgical intervention in pediatric patients, is often difficult to establish and potentially painful. AV300 uses near infrared laser light to improve visibility of peripheral veins and could help cannulating them. The aim of this study was to examine if use of Accuvein(®) AV300 vein viewer could facilitate venous cannulation in children.MethodsFrom January to March 2011, 238 consecutive pediatric patients (0-17 years) preceding surgical interventions were included. All participants including newborns, infants and children were allocated to groups [control group (124 patients) and intervention group (114 patients)] in a non-random way. Randomization was not feasible because data was acquired retrospectively from a clinical quality management project. In control group, peripheral IV cannulation was performed without supporting device, in intervention group with support of AV300. Time and number of attempts until successful venous cannulation were defined as primary end points.ResultsMedian time until successful cannulation was 2 min (range 0.1-20, quartiles: 25 %: 1; 75 %: 5) in the intervention group and 1 min (range 0.1-18, quartiles: 25 %: 0.2; 75 %: 2) in the control group (p < 0.01). Median number of attempts was higher in the intervention group (2; range 1-6, quartiles: 25 %: 1; 75 %: 3) than in the control group (1; range 1-6, quartiles: 25 %: 1; 75 %: 2, p < 0.01). Rate of cannulations successful at first attempt was 0.45 (51 of 114, 95 % CI 0.35-0.54) in the intervention group and 0.73 (90 of 124, 95 % CI 0.65-0.81) in the control group (p < 0.01).ConclusionsIn our study we were not able to reduce neither time nor number of attempts until a successful venous cannulation in children using the vein viewer. Given certain limitations of our study as the lack of randomization and no control for inter-operator variability, the conclusions drawn from it are also limited, but by our results laser-supported cannulation cannot be recommended for standard procedures.Trial RegistrationClinicalTrials.gov NCT01434537. Registered 29 July 2011.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.