• Systematic reviews · Jan 2013

    Individual patient data systematic review and meta-analysis of optic nerve sheath diameter ultrasonography for detecting raised intracranial pressure: protocol of the ONSD research group.

    • Julie Dubourg, Mahmoud Messerer, Dimitrios Karakitsos, Venkatakrishna Rajajee, Erik Antonsen, Etienne Javouhey, Alessandro Cammarata, Michael Cotton, Roy Thomas Daniel, Carmelo Denaro, Emmanuel Douzinas, C... more lément Dubost, Moncef Berhouma, Behrouz Kassai, Muriel Rabilloud, Antonino Gullo, Abderrhammane Hamlat, Gregorios Kouraklis, Giuseppe Mannanici, Keith Marill, Sybille Merceron, John Poularas, Giuseppe Ristagno, Vicki Noble, Sachita Shah, Heidi Kimberly, Gianluca Cammarata, Riccardo Moretti, and Thomas Geeraerts. less
    • Université Claude Bernard Lyon 1, 69003 Lyon, France. julie.dubourg@gmx.fr
    • Syst Rev. 2013 Jan 1;2:62.

    BackgroundThe purpose of the optic nerve sheath diameter (ONSD) research group project is to establish an individual patient-level database from high quality studies of ONSD ultrasonography for the detection of raised intracranial pressure (ICP), and to perform a systematic review and an individual patient data meta-analysis (IPDMA), which will provide a cutoff value to help physicians making decisions and encourage further research. Previous meta-analyses were able to assess the diagnostic accuracy of ONSD ultrasonography in detecting raised ICP but failed to determine a precise cutoff value. Thus, the ONSD research group was founded to synthesize data from several recent studies on the subject and to provide evidence on the diagnostic accuracy of ONSD ultrasonography in detecting raised ICP.MethodsThis IPDMA will be conducted in different phases. First, we will systematically search for eligible studies. To be eligible, studies must have compared ONSD ultrasonography to invasive intracranial devices, the current reference standard for diagnosing raised ICP. Subsequently, we will assess the quality of studies included based on the QUADAS-2 tool, and then collect and validate individual patient data. The objectives of the primary analyses will be to assess the diagnostic accuracy of ONSD ultrasonography and to determine a precise cutoff value for detecting raised ICP. Secondly, we will construct a logistic regression model to assess whether patient and study characteristics influence diagnostic accuracy.DiscussionWe believe that this IPD MA will provide the most reliable basis for the assessment of diagnostic accuracy of ONSD ultrasonography for detecting raised ICP and to provide a cutoff value. We also hope that the creation of the ONSD research group will encourage further study.Trial RegistrationPROSPERO registration number: CRD42012003072.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.