Eur J Cardiothorac Surg · May 2000
Pumpless extracorporeal lung assist - experience with the first 20 cases.
- A Liebold, C M Reng, A Philipp, M Pfeifer, and D E Birnbaum.
- Department of Cardiothoracic, University of Regensburg, Surgery, Franz-Josef-Strauss-Allee 11, 93042, Regensburg, Germany. andreas.liebold@klinik.uni-regensburg.de
- Eur J Cardiothorac Surg. 2000 May 1;17(5):608-13.
ObjectiveLong-term extracorporeal lung assist is limited by a significant mechanical blood trauma resulting in bleeding and hemolysis. To reduce the drawbacks of extracorporeal lung assist a new technique has been developed, by which the driving force for the extracorporeal circuit derives from the patients arterio-venous pressure gradient (pumpless extracorporeal lung assist). The aim of this clinical study was to test the feasibilty and effectiveness of pumpless extracorporeal lung assist in patients with acute respiratory distress syndrome.MethodsTwenty patients (41+/-16 years) with acute respiratory distress syndrome of various causes and failing respirator therapy were enrolled. The minimum hemodynamic requirements included a cardiac output (CO) >6 l/min and mean arterial pressure (MAP) >70 mmHg. Pumpless extracorporeal lung assist was established using a short circuit arterio-venous shunt including a special designed low-resistance membrane oxygenator which was placed between the patients legs.ResultsAt the time of inclusion FiO(2) in all patients was 1.0 (paO(2) 45.9+/-7 mmHg, paCO(2) 58.9+/-17 mmHg). After 24 h of pumpless extracorporeal lung assist FiO(2) was reduced to 0.8+/-0.1. A significant improvement in oxygenation (paO(2) 84.1+/-21 mmHg, P<0.05) and CO(2) removal (paCO(2) 32.7+/-5 mmHg, P<0.05) was notable. The mean extracorporeal flow was 2.6+/-0.6 l/min, which represented approximately 25% of the patients mean CO (10.8+/-2 l/min). The median assist time was 12+/-8 (1-32) days. Fifteen out of twenty patients were weaned off pumpless extracorporeal lung assist. Five out of twenty patients died while on the system (four sepsis, one ventricular fibrillation). Three out of twenty patients died after successful weaning on day 8, 30, and 50, respectively. Twelve out of twenty patients were discharged in a healthy state (overall survival 60%). Technical problems included thrombosis of the venous cannula (n=5), thrombus formation within the membrane oxygenator (n=2), membrane oxygenator plasma leakage (n=2), and membrane oxygenator contamination with Candida albicans. No bleeding complication was observed.ConclusionPumpless extracorporeal lung assist is feasible and effective in a selected group of patients with acute respiratory distress syndrome but preserved hemodynamic function. By eliminating the pump and reducing the tubing length blood trauma can be minimized. Being very simple the system entails fewer risks of technical complications and also facilitates nursing care.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.