• Critical care medicine · Apr 1993

    Verbal communication of ventilator-dependent patients.

    • J L Manzano, S Lubillo, D Henríquez, J C Martín, M C Pérez, and D J Wilson.
    • Hospital Nuestra Señora del Pino, Las Palmas de Gran Canaria, Canary Islands, Spain.
    • Crit. Care Med. 1993 Apr 1;21(4):512-7.

    ObjectiveTo assess whether communication capabilities of ventilator-dependent patients are improved by the use of the Passy-Muir unidirectional valve.DesignProspective study.SettingAn 18-bed multidisciplinary intensive care unit (ICU) at the University Hospital, Las Palmas, Spain.PatientsTen chronic ventilator-dependent patients who had undergone tracheostomy and met the following criteria: ability to eliminate tracheobronchial secretions in order to maintain a patent and unobstructed airway, adequate gas exchange while ventilated with an FIO2 of < or = 0.4 (Pao2 > 60 torr [8 kPa]), Paco2 of < 55 torr (7.3 kPa), normal hemodynamics without the need for administration of vasopressors, and normal mental state. Eight patients presented with pulmonary disease, and two presented with neuromuscular disease.Interventions And MethodsBefore attaching the Passy-Muir valve, the following procedures were performed: a) suction of tracheal and pharyngeal secretions; b) deflation of the tracheostomy tube cuff; c) increase in the ventilator's tidal volume setting to maintain the inspiratory pressure before cuff's deflation; d) set peak inspiratory pressure alarm and disconnect expiratory volume alarm. The valve was then connected between the tracheostomy tube and the Y-shaped piece of the ventilator's circuit. Respiratory movements, arterial blood gases, peak inspiratory pressure, respiratory rate, quantity of secretions, and changes in sense of smell were monitored during the study. The valve's efficacy was evaluated according to the patient's ability to talk and be understood during the entire respiratory cycle.ResultsThe Passy-Muir valve was effective in improving communication in eight of ten patients who, during its use, presented insignificant cardiorespiratory changes, decreased secretions, and effected considerable improvement in well-being. Its use was impossible in two patients: one with severe pulmonary disease because cuff deflation prevented adequate ventilation, and one patient with neuromuscular disease and laryngopharyngeal dysfunction.ConclusionsThe Passy-Muir unidirectional valve allows ventilator-dependent patients to talk and communicate without assistance. Patients felt better and were motivated to participate in their own care.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…