• J Clin Monit · Jan 1991

    Skin reflectance pulse oximetry: in vivo measurements from the forearm and calf.

    • Y Mendelson and M J McGinn.
    • Department of Biomedical Engineering, Worcester Polytechnic Institute, MA 01609.
    • J Clin Monit. 1991 Jan 1;7(1):7-12.

    AbstractThis study describes the results from a series of human experiments demonstrating the ability to measure arterial hemoglobin oxygen saturation (SaO2) from the forearm and calf using a reflectance pulse oximeter sensor. A special optical reflectance sensor that includes a heating element was interfaced to a temperature controller and a commercial Data-scope ACCUSAT pulse oximeter that was adapted for this study to perform as a reflectance pulse oximeter. The reflectance pulse oximeter sensor was evaluated in a group of 10 healthy adult volunteers during steady-state hypoxia. Hypoxia was induced by gradually lowering the inspired fraction of oxygen in the breathing gas mixture from 100 to 12%. Simultaneous SaO2 measurements obtained from the forearm and calf with two identical reflectance pulse oximeters were compared with SaO2 values measured by a finger sensor that was interfaced to a standard Datascope ACCUSAT transmittance pulse oximeter. The equations for the best-fitted linear regression lines between the percent reflectance, SpO2(r), and transmittance, SpO2(t), values in the range between 73 and 100% were SpO2(r) = -7.06 + 1.09 SpO2(t) for the forearm (n = 91, r = 0.95) and SpO2(r) = 7.78 + 0.93 SpO2(t) for the calf (n = 93, r = 0.88). The regression analysis of the forearm data revealed a mean +/- SD error of 2.47 +/- 1.66% (SaO2 = 90-100%), 2.35 +/- 2.45% (SaO2 = 80-89%), and 2.42 +/- 1.20% (SaO2 = 70-79%). The corresponding regression analysis of the calf data revealed a mean +/- SD error of 3.36 +/- 3.06% (SaO2 = 90-100%), 3.45 +/- 4.12% (SaO2 = 80-89%), and 2.97 +/- 2.75% (SaO2 = 70-79%).(ABSTRACT TRUNCATED AT 250 WORDS)

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.