J Paediatr Child Health · Jul 2009
Assessment of portable continuous wave Doppler ultrasound (ultrasonic cardiac output monitor) for cardiac output measurements in neonates.
- Sascha Meyer, David Todd, and Bruce Shadboldt.
- Centre for Newborn Care, Canberra Hospital, Woden, Australian Capital Territory 2606, Australia.
- J Paediatr Child Health. 2009 Jul 1;45(7-8):464-8.
Background And Study PurposeThe ultrasonic cardiac output monitoring (USCOM, USCOM Pty Ltd, Coffs Harbour, NSW, Australia) device provides a new method of non-invasively assessing cardiac output (CO). It has been successfully used in adults, but there have been few studies in neonates.AimsTo study the inter-operator reliability, and to compare the aortic (systemic) CO and pulmonary CO in a neonatal population.Patient And MethodsIn a study using the USCOM device, we have determined: (i) the inter-operator (rater) agreement for aortic (left ventricular output) and pulmonary (right ventricular output) CO; and (ii) by combining the measurements of aortic and pulmonary CO from each operator to obtain average aortic and pulmonary CO in neonates admitted to the neonatal unit during the first 8 days of life. Neonates with congenital heart disease were excluded from the study.ResultsTwelve neonates were enrolled in the study, and their mean gestational age was 34.1 +/- 3.7 weeks, mean birth weight 2.268 +/- 0.872 kg with eight boys and four girls. There was no significant difference in CO measurements between the two operators (inter-rater correlation = 0.93 (0.86-0.97 (95% CI), P < 0.0001). However, the mean aortic CO was significantly lower than the mean pulmonary CO (228 mL/kg/min (202-254 (95% CI)) versus 282 mL/kg/min (256-309 (95% CI), P= 0.006).ConclusionsAlthough there was a good correlation between operators, further investigations are required to study the discrepancy between aortic (systemic)/pulmonary CO in this population. Other than this discrepancy, the validity of this technique in neonates requires further detailed studies as it uses continuous wave Doppler for the measurements.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.