-
J. Cardiothorac. Vasc. Anesth. · Oct 2010
Comparative Study Clinical TrialComparison of uncalibrated arterial pressure waveform analysis with continuous thermodilution cardiac output measurements in patients undergoing elective off-pump coronary artery bypass surgery.
- Yong Bo Jeong, Tae Hee Kim, Young Jin Roh, In Cheol Choi, and Jeong Hun Suh.
- Department of Anesthesiology and Pain Medicine, Asan Medical Center, College of Medicine, University of Ulsan, Seoul, Korea.
- J. Cardiothorac. Vasc. Anesth. 2010 Oct 1;24(5):767-71.
ObjectiveMonitoring of cardiac output is required during anesthesia for off-pump coronary artery bypass (OPCAB) surgery. Recently, FloTrac, a new device for arterial pressure waveform analysis for cardiac output (APCO) monitoring without external calibration, was developed. The authors have compared APCO with STAT-mode continuous cardiac output (SCCO) in patients undergoing OPCAB surgery.DesignA clinical study.SettingA university hospital (single institution).ParticipantsThirty consecutive patients undergoing elective OPCAB surgery.InterventionsArterial pressure measurement with FloTrac, pulmonary arterial catheter insertion.Measurements And Main ResultsAPCO and SCCO measurements were recorded after pulmonary artery catheter insertion (T1), after sternotomy (T2), after heart positioning for left anterior descending artery anastomosis (T3, T4), after heart positioning for obtuse marginal artery anastomosis (T5, T6), after heart positioning for posterior descending artery anastomosis (T7, T8), and after sternal closure (T9). APCO and SCCO were compared using the Bland-Altman method and the percentage error by Critchley's criteria. SCCO and APCO ranged from 2.1 to 6.9 L/min and 1.2 to 7.4 L/min, respectively, and showed low correlation (r = 0.29). The overall bias by the Bland-Altman method between SCCO and APCO was -0.23 L/min, with a precision of -1.4 to 0.9 L/min, and the overall limits of agreement were -2.5 to 2.0 L/min. The overall mean CO was 4.0 ± 0.95 L/min. The overall percentage error between SCCO and APCO measurements was 57%.ConclusionsUncalibrated APCO values do not agree with thermodilution SCCO and significantly overestimated the SCCO in patients undergoing OPCAB surgery. Further evaluation is required to verify the clinical acceptance of FloTrac APCO in OPCAB surgery.Copyright © 2010 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.