-
Reg Anesth Pain Med · Mar 1999
Randomized Controlled Trial Comparative Study Clinical TrialContinuous spinal anesthesia: a comparative study of standard microcatheter and Spinocath.
- J De Andrés, J C Valía, A Olivares, and J Bellver.
- Department of Anesthesiology, Critical Care, and Pain Therapy, Valencia General Hospital, Spain.
- Reg Anesth Pain Med. 1999 Mar 1;24(2):110-6.
Background And ObjectivesThis prospective, randomized study evaluated the advantages and disadvantages of a new subarachnoid catheter.MethodsSixty ASA I-IV patients aged 40-70 years, scheduled for total knee arthroplasty, were randomly distributed into group 1 (Spinocath; Braun Melsungen, Germany) and group 2 (Intralong; Pajunk, Germany). The study tabulated details of subarachnoid catheter insertion, dural puncture, time to free cerebrospinal fluid (CSF) flow, anesthesia onset time, surgery anesthesia time, the upper level of sensory block reached, the anesthesiologist-evaluated degree of difficulty with the technique, and the quality of analgesia obtained and complications. At the end of surgery, all the catheters were removed, and their patency was checked.ResultsSpinocath insertion required 6.3 +/- 3.2 minutes in group 1 versus 3.9 +/- 1.2 minutes in group 2 (P < .01) with similar difficulties with catheter introduction. Perception of dural puncture was better in group 1 (P < .05). There were significant intergroup differences in time to free flow of CSF through the catheter. In group 2, correct catheter positioning had to be confirmed by aspiration in 80% of cases (P < .05). At the end of surgery, the catheters were removed, and there were no significant differences between groups. The anesthetic blocks were similar with both systems. Patient opinion of the technique did not differ between groups, and regression analysis did not show any differences between groups or correlation to any incident during performance of the technique. Globally, the anesthesiologists participating in the study considered both systems to be easy to use and adequate for continuous spinal anesthesia. With respect to the advantage afforded by a directional needle in orientating the catheter within the spinal canal, the Spinocath system-with a longer technique performance time than the standard approach-involves a success rate and incidence of technical problems similar to that of the conventional technique.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.