• Obesity surgery · Mar 2005

    Continuous positive airway pressure (CPAP) changes in bariatric surgery patients undergoing rapid weight loss.

    • D Alan Lankford, Charles D Proctor, and Robert Richard.
    • Sleep Disorders Center of Northeast Georgia Medical Center, Gainesville, GA 30342, USA. alankford@sleepsciences.com
    • Obes Surg. 2005 Mar 1;15(3):336-41.

    BackgroundObstructive sleep apnea (OSA) is a common condition in morbidly obese patients, with the reported prevalence ranging from 12-78%. There is increasing recognition of the need to diagnose and treat/manage OSA both preoperatively and postoperatively. Nasal CPAP is the preferred treatment of OSA; however, weight loss is associated with a reduction in required pressures. We evaluated the CPAP pressure requirements in a group of patients undergoing rapid weight loss following Roux-en-Y gastric bypass.Methods15 patients who had been diagnosed with OSA before surgery were retrospectively evaluated. All patients had demonstrated compliance on home CPAP therapy, were minimally 3 months post-surgery and had follow-up reports that their CPAP was less effective. We obtained data on age, sex, weight, BMI, and apnea/hypopnea index (AHI). Optimal CPAP pressure was obtained initially through attended in-laboratory complex polysomnography. Follow-up CPAP pressure was obtained using an auto-titrating PAP device at home. These data were used to evaluate the pressure changes that accompanied weight loss.ResultsThis group of patients had lost an average of 44.5 +/- 19.4 kg. Four patients had achieved their goal weight. Their starting CPAP pressures averaged 11 +/- 3.0 cm H2O, with a range of 7-18 cm H2O. Follow-up CPAP pressures averaged 9 +/- 2.7 cm H2O, with a range of 4-12 cm H2O, representing an overall reduction of 18%. The subgroup of patients who had achieved goal weight had a pressure reduction of 22% (9 +/- 2.0 to 7 +/- 1.0 cm H2O).ConclusionCPAP pressure requirements change considerably in bariatric surgery patients undergoing rapid weight loss. Auto-titrating PAP devices have promise for facilitating the management of CPAP therapy during this time. Consideration should also be given to the use of autotitrating PAP units as the treatment of choice in these patients.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…