• Blood pressure monitoring · Aug 2008

    Comparative Study

    Comparison of a radial artery compression device with invasive radial artery blood pressure monitoring.

    • Megan L Fix, Joshua N Goldstein, Todd M Listwa, Sara W Nelson, and Stephen H Thomas.
    • Massachusetts General Hospital, Boston, MA, USA. meganfix@gmail.com
    • Blood Press Monit. 2008 Aug 1;13(4):199-203.

    ObjectiveThe goal of this study was to validate the accuracy of the Primo radial artery compression device (RACD) according to the guidelines recommended by the American National Standards Institute/Association for the Advancement of Medical Instrumentation (AAMI) SP10-2002 Standards for Electronic or Automated Sphygmomanometers.MethodsA prospective, nonblind, convenience sample trial at a level 1 trauma center (annual emergency department census 70,000) enrolled 17 adult patients with preexisting radial artery line catheters (RAL). Each patient had 10 blood pressure measurements giving an n=170. This number is consistent with calculations on the basis of the American National Standards Institute/AAMI guidelines.ResultsThe mean arterial pressures (MAPs), systolic blood pressures (SBPs), and diastolic blood pressures (DBPs) measured by both the RACD and the RAL were compared. The R for the RAL/RACD were 0.94, 0.96, and 0.85 for MAP, SBP, and DBP, respectively (P<0.05). The mean difference between the RAL MAP and the RACD MAP was +1.0 mmHg (95% confidence interval, -1.69 to -0.33). The mean SBP difference was -2.8 mmHg (SD 6.4 mmHg) and the mean DBP difference was +2.6 mmHg (SD 5.7 mmHg).ConclusionThe RACD meets the guidelines for automated blood pressure monitors set by the AAMI SP10-2002 Standards for Electronic or Automated Sphygmomanometers with an accuracy of +/- 5 mmHg and SD of 8 mmHg or less for both SBP and DBP measurements.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.