-
- Ozcan Kahraman Buse B *Dokuz Eylül University, School of Physical Therapy and Rehabilitation, Izmir, Turkey†Dokuz Eylül University, Faculty of Medicine, Department of Neu, Salik Sengul Yesim Y, Turhan Kahraman, and Orhan Kalemci.
- *Dokuz Eylül University, School of Physical Therapy and Rehabilitation, Izmir, Turkey†Dokuz Eylül University, Faculty of Medicine, Department of Neurosurgery, Izmir, Turkey.
- Spine. 2016 Jul 15; 41 (14): E844-50.
Study DesignTest-retest design.ObjectiveThe objective was to examine the intrarater (test-retest) reliability of the core stability related tests and to develop a reliable core stability assessment battery.Summary Of Background DataStudies suggest that core stability exercises may improve function and decrease pain in patients with nonspecific low back pain (LBP). Reliable clinical tests are required to implement adequate rehabilitation and to evaluate results of these interventions.MethodsThe study had a test-retest design. Thirty-three different tests that might relate to core stability were identified with their mostly used protocols. Five different components of core stability including endurance, flexibility, strength, functional performance, and motor control were assessed in 38 patients with nonspecific LBP. The same testing procedure was performed again after 48 to 72 hours. Intraclass correlation coefficients (ICCs), standard error of measurement, and minimal detectable change were calculated to assess the intrarater reliability.ResultsThe intrarater reliability of the tests ranged from little to very high (ICC = 0.08-0.98). Partial curl-up (ICC = 0.90), lateral bridge (ICC = 0.95-0.96), trunk flexor endurance (ICC = 0.97), sit and reach (ICC = 0.98), single-legged hop (ICC = 0.98-0.97), lateral step-down (ICC = 0.93-0.92), eyes open right and left leg unilateral stance (ICC = 0.97 and 0.91) tests had the highest intrarater reliability for each core stability component.ConclusionThe results indicated that the partial curl-up test (strength), side bridge and trunk flexor tests (endurance), sit-and-reach test (flexibility), single-legged hop, and lateral step-down (functional), unilateral stance test with eyes open (motor control) had very high intrarater reliability. A core stability assessment battery involving these tests can be used in patients with nonspecific LBP to assess all components of core stability.Level Of Evidence3.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.