J. Thorac. Cardiovasc. Surg. · Jul 1996
Euro-Collins solution exacerbates lung injury in the setting of high-flow reperfusion.
- N F DeLima, O A Binns, S A Buchanan, M C Mauney, J T Cope, K S Shockey, C G Tribble, and I L Kron.
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, University of Virginia Health Sciences Center, Charlottesville, VA, USA.
- J. Thorac. Cardiovasc. Surg. 1996 Jul 1;112(1):111-6.
AbstractSingle-lung transplantation has been abandoned for the treatment of pulmonary hypertension by many centers because of overperfusion of the graft following implantation. Euro-Collins solution is currently used for lung preservation despite the vasoconstrictive effect of this intracellular-type solution. We hypothesized that high-flow reperfusion, alone or in combination with Euro-Collins-induced vasoconstriction, may cause lung dysfunction. Twenty-eight New Zealand White rabbit lungs were harvested and studied in an isolated, blood-perfused model of lung function after 4 hours of cold ischemia. Control lungs were preserved with 50 ml/kg cold saline solution flush and reperfused at either normal flow (60 ml/min) or high flow (120 ml/min). Experimental lungs were preserved with 50 ml/kg cold Euro-Collins solution and reperfused at normal or high flow rates. The arteriovenous oxygen gradient at the end of the 30-minute reperfusion period was significantly lower in the high-flow versus the low-flow experimental group (31.1 +/- 4.2 vs 130.6 +/- 41.6 mm Hg, p < 0.05). The pulmonary vascular resistance was increased in the high-flow groups and the experimental groups, with a statistically significant difference between low-flow experimental and control groups (64374.4 +/- 5722.6 vs 37041.5 +/- 2110.9 dynes x sec x cm(-5), p < 0.001). The percentage decrease in dynamic airway compliance in the high-flow experimental group was markedly different from that in the high-flow control group (-51% +/- 13.3% vs -10.15% +/- 3.4%, p < 0.05). Similarly, the wet/dry ratio of the lungs in the high-flow experimental group (13.92 +/- 2.32) was significantly greater than that in the low-flow experimental group (6.27 +/- 0.19, p < 0.01) and than that in the high-flow control group (5.88 +/- 0.23, p < 0.001). These data demonstrate that high-flow reperfusion and preservation with Euro-Collins solution are deleterious to lung function, both individually and in combination, in an ex vivo rabbit lung model. Lung preservation with Euro-Collins solution may not be optimal when high-flow reperfusion is anticipated, as in the setting of unilateral lung transplantation for pulmonary hypertension.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.