• Acad Emerg Med · Apr 2012

    Multicenter Study

    Feasibility of percutaneous vagus nerve stimulation for the treatment of acute asthma exacerbations.

    • James R Miner, Lawrence M Lewis, Giselle S Mosnaim, Joseph Varon, Daniel Theodoro, and Thomas J Hoffmann.
    • Department of Emergency Medicine, Hennepin County Medical Center, Minneapolis, MN, USA. miner015@umn.edu
    • Acad Emerg Med. 2012 Apr 1;19(4):421-9.

    ObjectivesThis study assessed the feasibility of an investigational vagus nerve stimulation (VNS) device for treating acute asthma exacerbations in patients not responding to at least 1 hour of initial standard care therapy.MethodsThis was a prospective, nonrandomized study of patients treated in the ED for moderate to severe acute asthma (forced expiratory volume in 1 second [FEV(1)] 25% to 70% of predicted). Treatment entailed percutaneous placement of an electrode near the right carotid sheath and 60 minutes of VNS and continued standard care. VNS voltage was adjusted to perceived improvement, muscle twitching, or adverse events (AEs). All AEs, vital signs, FEV(1), perceived work of breathing (WOB), and final disposition were recorded.ResultsTwenty-five subjects were enrolled. There were no serious AEs and no significant changes in vital signs. No subject required terminating VNS. One patient had minor bleeding from the procedure, and one had a hematoma and withdrew prior to VNS. AEs related to VNS were temporary and included cough (1 of 24), swallowing difficulty (2 of 24), voice change (2 of 24), and muscle twitching (14 of 24). These resolved when VNS ended. The FEV(1) improved at 15 minutes (median = 15.8%, 95% confidence interval [CI] = 9.3% to 22.4%), 30 minutes (median = 21.3%, 95% CI = 8.1% to 36.5%), and 60 minutes (median = 27.5%, 95% CI = 11.3% to 43.5%). WOB improved at 15 minutes (median = 53.9%, 95% CI = 33.7% to 73.9%), 30 minutes (median = 69.1%, 95% CI = 56.4% to 81.8%), and 60 minutes (median = 81.0%, 95% CI = 68.5% to 93.5%).ConclusionsPercutaneous VNS did not result in serious AEs and was associated with improvements in FEV(1) and perceived dyspnea. Percutaneous VNS appears to be feasible for use in the treatment of moderate to severe acute asthma in patients unresponsive to initial standard care treatment.© 2012 by the Society for Academic Emergency Medicine.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…