Agreement of cardiac output measurement between pulse contour analysis and thermodilution in various body positions: a porcine study.
- Ping-Cheng Shih, Yu-Chun Hung, Ying-Lun Chen, Hsin-Jung Tsai, Chia-Ying Chen, and Chun-Jen Huang.
- Department of Anesthesiology, Buddhist Tzu Chi General Hospital, Taipei Branch, Taipei, Taiwan.
- J. Surg. Res. 2013 May 1;181(2):315-22.
BackgroundWe elucidated the effects of various body positions on the agreement of cardiac output (CO) measurement between pulse contour analysis with the PiCCO monitor and thermodilution with pulmonary artery catheterization.MethodsFifteen anesthetized and mechanically ventilated pigs (40 ± 2 kg) were sequentially placed in various positions to facilitate simultaneous CO measurement. Between-methods agreement was assessed using the Bland-Altman method. Trending ability was assessed using Pearson product-moment correlation coefficient analysis.ResultsIn supine, reverse Trendelenburg, Trendelenburg, and left lateral decubitus (lateral) positions, CO measured by these two methods was comparable (4.9 ± 1.5 versus 4.6 ± 1.6 L/min, 4.6 ± 2.2 versus 4.8 ± 1.8 L/min, 5.1 ± 2.1 versus 4.9 ± 2.1 L/min, and 5.4 ± 1.8 versus 5.0 ± 1.6 L/min; all P > 0.05). Mean bias between methods and limits of agreement (percentage error) were 0.3 ± 2.9 L/min (61%), -0.3 ± 3.3 L/min (71%), 0.1 ± 4.1 L/min (77%), and 0.5 ± 3.7 L/min (71%). Directional changes of paired CO revealed 66% (reverse Trendelenburg), 57% (Trendelenburg), and 66% (lateral) concordance. The correlation coefficient (r(2)) was 0.199, 0.127, and 0.108. For paired CO ≤6 L/min, mean bias between methods and limits of agreement (percentage error) were 0.2 ± 1.0 L/min (25%), -0.1 ± 1.0 L/min (28%), 0.2 ± 1.1 L/min (29%), and 0.5 ± 0.9 L/min (23%). Directional changes of paired CO revealed 84% (reverse Trendelenburg), 76% (Trendelenburg), and 65% (lateral) concordance. The correlation coefficient (r2) was 0.583, 0.626, and 0.213.ConclusionsThe mean CO measured by pulse contour analysis and thermodilution did not agree well in various body positions. Moreover, the measurements tended to trend differently in response to positional changes. For paired CO ≤6 L/min, however, the between-methods agreement and the trending ability improved significantly.Copyright © 2013 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.