• Anesthesiology · Sep 1993

    Comparative Study

    Continuous calculation of intratracheal pressure in tracheally intubated patients.

    • J Guttmann, L Eberhard, B Fabry, W Bertschmann, and G Wolff.
    • Department of Surgery, University of Basel, Switzerland.
    • Anesthesiology. 1993 Sep 1;79(3):503-13.

    BackgroundIntratracheal pressure (Ptrach) should be the basis for analysis of lung mechanics. If measured at all, Ptrach is usually assessed by introducing a catheter into the trachea via the lumen of the endotracheal tube (ETT). The authors propose a computer-assisted method for calculating Ptrach on a point-by-point basis by subtracting the flow-dependent pressure drop delta PETT(V) across the ETT from the airway pressure (P(aw)), continuously measured at the proximal end of the ETT.MethodsThe authors measured the pressure-flow relationship of adult endotracheal tubes with different diameters (ID, 7-9 mm) at different lengths and of tracheostomy tubes (ID, 8-10 mm) in the laboratory. The coefficients of an approximation equation were fitted to the measured pressure-flow curves separately for inspiration and expiration. In 15 tracheally intubated patients under volume-controlled ventilation and spontaneous breathing, the calculated Ptrach was compared with the measured Ptrach.ResultsThe authors present the coefficients of the "nonlinear approximation": delta PETT = K1.VK2, with delta PETT being the pressure drop across the ETT and K1 and K2 being the coefficients relating V to delta PETT. An important result was an inspiration/expiration asymmetry: the pressure drop caused by the inspiratory flow exceeds that of the expiratory flow. A complete description of the pressure-flow relationship of an ETT, therefore, requires a set of four coefficients: K1I, K2I, K1E, and K2E. The reason for this asymmetry is the abrupt sectional change between ETT and trachea and the asymmetric shape of the swivel connector. Comparison of calculated and measured Ptrach in patients gives a correspondence within +/- 1 cmH2O (mean limits of agreement). The mean root-mean-square (rms) deviation is 0.55 cmH2O.ConclusionsPtrach can be monitored by combining our ETT coefficients and the flow and airway pressure continuously measured at the proximal end of the ETT.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.