• Crit Care Resusc · Sep 2008

    Comparative Study Clinical Trial

    Evaluation of a continuous glucose monitor in an unselected general intensive care population.

    • Grant C Price, Karen Stevenson, and Timothy S Walsh.
    • Department of Anaesthesia, Critical Care and Pain Medicine, Royal Infirmary of Edinburgh, Edinburgh, UK. Grant.Price@luht.scot.nhs.uk
    • Crit Care Resusc. 2008 Sep 1;10(3):209-16.

    ObjectiveTo assess the accuracy of the Guardian REALTime continuous glucose monitoring system (Medtronic MiniMed, Northridge, Calif, USA) in critically ill adults compared with standard bedside point-of-care testing of capillary and arterial blood glucose levels.SettingAn 18-bed mixed university tertiary referral intensive care unit, July to December 2006.Main Outcome MeasuresGlucose measurements by the Guardian subcutaneous monitoring system were compared with simultaneous measurements of capillary and arterial blood glucose levels. Correlation between the different methods was determined by linear regression, using capillary blood glucose values as the "gold standard", and was further analysed by Bland and Altman plots.Results17 emergency-admission mechanically ventilated adults were studied. A total of 1101 glucose measurements were available for analysis (from Guardian, 371; capillary blood samples, 373; and arterial blood samples, 357). With an a-priori acceptable difference of +/-1mmol/L, the Guardian system did not perform well enough to replace current methods of glucose measurement. There was also significant discrepancy between arterial and capillary blood glucose measurements. These common methods of intermittent blood glucose sampling are therefore not interchangeable.ConclusionThe Guardian REAL-Time continuous glucose monitoring system cannot replace current methods of blood glucose measurement at a glucose threshold of +/-1mmol/L. It may have role as an early warning detection system for hypo- or hyperglycaemia, but this needs to be evaluated in a prospective study of extremes of blood glucose levels in a critically ill population. Glucose measurements in arterial and capillary blood samples with a point-of-care glucometer also showed wide discrepancies.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.