• Br J Anaesth · Jun 2011

    Clinical Trial

    Performance of cardiac output measurement derived from arterial pressure waveform analysis in patients requiring high-dose vasopressor therapy.

    • S Metzelder, M Coburn, M Fries, M Reinges, S Reich, R Rossaint, G Marx, and S Rex.
    • Department of Anaesthesiology, University Hospital of the RWTH Aachen, Pauwelsstr. 30, D-52074 Aachen, Germany.
    • Br J Anaesth. 2011 Jun 1;106(6):776-84.

    BackgroundArterial pressure waveform analysis of cardiac output (APCO) without external calibration (FloTrac/Vigileo™) is critically dependent upon computation of vascular tone that has necessitated several refinements of the underlying software algorithms. We hypothesized that changes in vascular tone induced by high-dose vasopressor therapy affect the accuracy of APCO measurements independently of the FloTrac software version.MethodsIn this prospective observational study, we assessed the validity of uncalibrated APCO measurements compared with transpulmonary thermodilution cardiac output (TPCO) measurements in 24 patients undergoing vasopressor therapy for the treatment of cerebral vasospasm after subarachnoid haemorrhage.ResultsPatients received vasoactive support with [mean (sd)] 0.53 (0.46) µg kg(-1) min(-1) norepinephrine resulting in mean arterial pressure of 104 (14) mm Hg and mean systemic vascular resistance of 943 (248) dyn s(-1) cm(-5). Cardiac output (CO) data pairs (158) were obtained simultaneously by APCO and TPCO measurements. TPCO ranged from 5.2 to 14.3 litre min(-1), and APCO from 4.1 to 13.7 litre min(-1). Bias and limits of agreement were 0.9 and 2.5 litre min(-1), resulting in an overall percentage error of 29.6% for 68 data pairs analysed with the second-generation FloTrac(®) software and 27.9% for 90 data pairs analysed with the third-generation software. Precision of the reference technique was 2.6%, while APCO measurements yielded a precision of 29.5% and 27.9% for the second- and the third-generation software, respectively. For both software versions, bias (TPCO-APCO) correlated inversely with systemic vascular resistance.ConclusionsIn neurosurgical patients requiring high-dose vasopressor support, precision of uncalibrated CO measurements depended on systemic vascular resistance. Introduction of the third software algorithm did not improve the insufficient precision (>20%) for APCO measurements observed with the second software version.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…