• Zhonghua yi xue za zhi · Aug 2011

    Randomized Controlled Trial Comparative Study

    [Effects of different ventilation mode on pulmonary function during minor operation of general anesthesia with SLIPA laryngeal mask].

    • Lin-guang Gan and Jun-ping Chen.
    • Department of Anesthesiology, Second Hospital of Ningbo, Ningbo, China. glgwenzhou@yahoo.com.cn
    • Zhonghua Yi Xue Za Zhi. 2011 Aug 30;91(32):2261-3.

    ObjectiveTo retrospectively analyze the effects of different ventilation modes on pulmonary function during minor operation of general anesthesia with streamlined liner of the pharynx airway (SLIPA) laryngeal mask and assess its safety of spontaneous respiration during general anesthesia.MethodsA total of 76 adult patients (aged 28 - 44 years old, American Society of Anesthesiologists physical status I-II) scheduled for operations were randomly allocated into the mechanical ventilation and spontaneous respiration group (n = 38 each). Anesthetic induction was performed intravenously with propofol (2 mg/kg), sulfentanyl (0.5 µg/kg) and cisatracurium besylate (0.3 mg/kg) (in mechanical ventilation group). Anesthesia was maintained by sevoflurane at 0.7 minimum alveolar concentration (MAC), mixture of atmosphere and oxygen at 1:1 and a continuous infusion of propofol at the speed of 4 mg×kg(-1)h(-1). Neostigmine (2 mg) and atropine (1 mg) were administered intravenously before the extraction of SLIPA laryngeal mask in order to antagonize the residual effects of muscle relaxation. The parameters including heart rate (HR), mean blood pressure (MAP) and end-tidal pressure of CO(2) (P(ET)CO(2)), blood gas analysis and the alveolar-arterial oxygen gradient [P(A-a)DO(2)], respiratory index (RI) and dead volume/tidal volume (V(D)/V(T)) were calculated at Different time points.ResultsNo significant differences were found in HR (spontaneous respiration group: 76 ± 7, 78 ± 6, 79 ± 7/min; mechanical ventilation group: 77 ± 6, 80 ± 5, 79 ± 6/min), MAP (spontaneous respiration group: 91 ± 10, 89 ± 9, 90 ± 9mm Hg; mechanical ventilation group: 89 ± 10, 88 ± 9, 92 ± 8) mm Hg at the monitored time points between two groups (P > 0.05). At the time of 30 min and 60 min after insertion, the pH value was significantly lower in spontaneous respiration group (7.351 ± 0.028, 7.338 ± 0.025) than those in mechanical ventilation group (7.391 ± 0.031, 7.389 ± 0.032). The values of PaCO(2) (42 ± 4, 46 ± 6) mm Hg and P(ET)CO(2) (41 ± 5, 45 ± 3) mm Hg were higher than those in mechanical ventilation group (37 ± 3, 35 ± 5; 37 ± 4, 36 ± 4) mm Hg (P < 0.05). No significant difference was found in the P(A-a)DO(2), RI or V(D)/V(T) at the monitored time points between two groups (P > 0.05).ConclusionNeither mechanical ventilation mode nor spontaneous respiration ventilation mode has any effect upon pulmonary function by during minor operation of general anesthesia with SLIPA laryngeal mask. Spontaneous respiration can offer a sufficient supply of oxygen but it carries the risk of CO(2) accumulation.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.