    Noninvasive versus invasive assessment of cardiac output after cardiac surgery: clinical validation.

    • D R Spahn, E R Schmid, M Tornic, R Jenni, L von Segesser, M Turina, and A Baetscher.
    • Division of Cardiovascular Anesthesia, University Hospital, Zurich, Switzerland.
    • J Cardiothorac Anesth. 1990 Feb 1;4(1):46-59.

    AbstractThe accuracy of noninvasive cardiac output (CO) measurement techniques, such as electrical bioimpedance (BIO), suprasternal continuous-wave Doppler (CWD), pulsed-wave Doppler (PWD), and transesophageal continuous-wave Doppler (TED) ultrasound has been variably judged in recent years. In addition, clinical comparisons are hampered by the fact that there is no generally accepted gold standard in CO measurement. After coronary artery bypass surgery in 25 patients, CO was simultaneously determined by invasive standard techniques (thermodilution [TD] and Fick methods) plus BIO, CWD, PWD, and TED. There was an excellent agreement found between TD and the Fick method (COF = 0.13 + 1.01.COTD; r = 0.96; n = 99). Thermodilution was thus chosen to be the reference method. Bioimpedance underestimated COTD (COBIO = 0.47 + 0.60.COTD; r = 0.78; n = 111). Allowing physiological ejection times only led to an improved agreement between BIO and TD (COBIO = 0.05 + 0.69.COTD; r = 0.82; n = 79), but BIO still significantly underestimated COTD (P less than 0.0005). Using physiologic ejection times during COCWD determination reduced the scatter of data as compared with TD; however, CWD still considerably overestimated COTD, when COCWD computation was based on the echocardiographic aortic diameter (ECHO) (COCWD ECHO = 0.79 + 1.40.COTD; r = 0.84; n = 52). With the surgical aortic diameter (SURG), the agreement improved (COCWD SURG = 0.75 + 1.16.COTD; r = 0.89; n = 44), but overestimation of COTD remained significant (P less than 0.05). Irrespective of the aortic diameter, COPWD values showed a considerable scatter of data compared with COTD (COPWD ECHO = 1.26 + 0.60.COTD; r = 0.62; n = 64 and COPWD SURG = 1.42 + 0.41.COTD; r = 0.47; n = 61). Correlation of absolute COTED values to thermodilution depended on the method used for calibration. All investigated noninvasive CO measurement techniques unreliably measured relative CO changes. Despite its invasiveness, TD remains the method of choice for accurate CO determination in adult patients following cardiac surgery.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…