    A randomized double-blind placebo-controlled dose-escalation phase 1 study of aerosolized amikacin and fosfomycin delivered via the PARI investigational eFlow® inline nebulizer system in mechanically ventilated patients.

    • A Bruce Montgomery, Shirley Vallance, Tammy Abuan, Markus Tservistas, and Andrew Davies.
    • 1 Cardeas Pharma , Seattle, WA.
    • J Aerosol Med Pulm Drug Deliv. 2014 Dec 1;27(6):441-8.

    BackgroundThis clinical trial evaluated the pharmacokinetics and safety/tolerability of amikacin/fosfomycin solution using a vibrating plate nebulizer, in mechanically ventilated patients with ventilator-associated tracheobronchitis (VAT) or ventilator-associated pneumonia (VAP).MethodsNine adult patients were consented to receive three escalating doses of a combination of 50 mg/mL amikacin and 20 mg/mL fosfomycin; doses were separated by 24±2 hr. On day 3, patients received two blinded, randomized treatments (amikacin/fosfomycin and volume-matched placebo), separated by 2 hr. All treatments were administered with a single-patient, multitreatment nebulizer (Investigational eFlow(®) Inline Nebulizer System; PARI Pharma GmbH, positioned in the inspiratory limb tubing between the ventilator and the patient. The nebulizer remained in-line until all treatments had been delivered. Concentrations of amikacin and fosfomycin were measured in tracheal aspirate and plasma samples obtained during the 24 hr after each dose.ResultsFifteen minutes after dosing with the 300/120 mg amikacin/fosfomycin combination, tracheal aspirate amikacin concentrations±SD were 12,390±3,986 μg/g, and fosfomycin concentrations were 6,174±2,548 μg/g (n=6). Airway clearance was rapid. Plasma concentrations were subtherapeutic; the highest observed amikacin plasma concentration was 1.4 μg/mL, and the highest observed fosfomycin plasma concentration was 0.8 μg/mL. Administration time was approximately 2 min/mL. No adverse effects on respiratory rate, peak airway pressures, or oxygenation were observed during or following drug or placebo administration.ConclusionsHigh tracheal aspirate concentrations of amikacin and fosfomycin were achieved in mechanically ventilated patients with VAT or VAP after aerosolized administration with an inline nebulizer system. Airway clearance was rapid. No adverse respiratory effects were noted during or following drug administration.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…