• Epilepsy research · Mar 2011

    3D visualization of subdural electrode shift as measured at craniotomy reopening.

    • Peter S LaViolette, Scott D Rand, Benjamin M Ellingson, Manoj Raghavan, Sean M Lew, Kathleen M Schmainda, and Wade Mueller.
    • Department of Biophysics, Medical College of Wisconsin, Milwaukee, WI 53226, USA. plaviole@mcw.edu
    • Epilepsy Res. 2011 Mar 1;94(1-2):102-9.

    PurposeSubdural electrodes are implanted for recording intracranial EEG (iEEG) in cases of medically refractory epilepsy as a means to locate cortical regions of seizure onset amenable to surgical resection. Without the aid of imaging-derived 3D electrode models for surgical planning, surgeons have relied on electrodes remaining stationary from the time between placement and follow-up resection. This study quantifies electrode shift with respect to the cortical surface occurring between electrode placement and subsequent reopening.MethodsCT and structural MRI data were gathered following electrode placement on 10 patients undergoing surgical epilepsy treatment. MRI data were used to create patient specific post-grid 3D reconstructions of cortex, while CT data were co-registered to the MRI and thresholded to reveal electrodes only. At the time of resective surgery, the craniotomy was reopened and electrode positions were determined using intraoperative navigational equipment. Changes in position were then calculated between CT coordinates and intraoperative electrode coordinates.ResultsFive out of ten patients showed statistically significant overall magnitude differences in electrode positions (mean: 7.2mm), while 4 exhibited significant decompression based shift (mean: 4.7mm), and 3 showed significant shear displacement along the surface of the brain (mean: 7.1mm).DiscussionShift in electrode position with respect to the cortical surface has never been precisely measured. We show that in 50% of our cases statistically significant shift occurred. These observations demonstrate the potential utility of complimenting electrode position measures at the reopening of the craniotomy with 3D electrode and brain surface models derived from post-implantation CT and MR imaging for better definition of surgical boundaries.Copyright © 2011 Elsevier B.V. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…