Comparative Study
Comparison of cardiac output measurements between NICO and the pulmonary artery catheter during repeat surgery for total hip replacement.
- G Gueret, G Kiss, S Khaldi, R Le Jouan, A Le Grand, Y Perrament, C Lefèvre, and C C Arvieux.
- University Hospital, Anesthesiology and Critical Care Department, La Cavale Blanche, Brest, France. gildas.gueret@chu-brest.fr
- Eur J Anaesthesiol. 2007 Dec 1;24(12):1028-33.
ObjectiveThe aim of this study was to compare cardiac output measurements of the non-invasive cardiac output and the pulmonary artery catheter during repeat surgery for hip replacement.MethodsIn this prospective observational study, patients undergoing repeat hip surgery who needed a pulmonary artery catheter were included. A standard protocol was followed for induction, endotracheal intubation and maintenance of anaesthesia (sufentanil, etomidate, sevoflurane, cisatracurium). After endotracheal intubation, the non-invasive cardiac output was connected and a pulmonary artery catheter was inserted. Data were collected every 3 min until patients were extubated.ResultsTen patients were included and 2455 points of comparison recorded. Cardiac output from the pulmonary artery catheter varied from 1.7 to 8.9 L min(-1) (mean 4.1 L min(-1)) and the non-invasive cardiac output (using averaging mode) from 1.7 to 8.0 L min(-1) (mean 3.7 L min(-1)). There was a significant correlation between them (P < 0.01; bias 0.3 L min(-1); limits of agreement +1.9 and -2.5 L min(-1)), although these differed between patients.ConclusionThe perioperative bias was small and the non-invasive cardiac output slightly underestimated cardiac output intraoperatively compared to the pulmonary artery catheter. The bias was smaller when mean cardiac output was below 3 L min(-1). Core temperature between 34.4 degrees C and 37.6 degrees C had no influence on the differences.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.