• Anesthesia and analgesia · Aug 2005

    Randomized Controlled Trial Comparative Study Clinical Trial

    The influence of lumbosacral cerebrospinal fluid volume on extent and duration of hyperbaric bupivacaine spinal anesthesia: a comparison between seated and lateral decubitus injection positions.

    • Hideyuki Higuchi, Yushi Adachi, and Tomiei Kazama.
    • Department of Anesthesia, Self Defense Force Hanshin Hospital, Hyogo, Japan. higu-chi@ka2.so-net.ne.jp
    • Anesth. Analg. 2005 Aug 1;101(2):555-60, table of contents.

    UnlabelledWe designed the present study to examine the influence of lumbosacral cerebrospinal fluid (CSF) volume on the spread and duration of hyperbaric bupivacaine spinal anesthesia when the injection is made with the patient in the lateral position compared with that when the patient is in a seated position. Seventy-four patients undergoing peripheral orthopedic or urogenital surgery with spinal block were enrolled. Lumbosacral CSF volumes were calculated from axial magnetic resonance images. Patients were randomly assigned to 1 of 2 groups: the lateral (L) and seated (S) groups (n = 37 each). Spinal anesthesia (3 mL hyperbaric 0.5% bupivacaine) was administered using a 25-gauge pencil-type needle with the needle aperture directed cephalad and the patient in the lateral decubitus position with the non-operated side up (L group) or with the patient in a seated position (S group). Patients were turned supine immediately after spinal injection (L group) or after remaining seated for 2 min (S group). Statistical correlation coefficients (rho) were assessed using Spearman's rank correlation. There were negative correlations between CSF volume and peak sensory block level in both the L (rho = -0.69, P < 0.0001) and S groups (rho = -0.68, P < 0.0001). In the S group, but not in the L group, CSF volume significantly correlated with onset time of peak sensory block level (rho = -0.48, P = 0.004), and time required for regression to L1-4 (P < 0.05-0.01). We conclude that CSF volume influences the spread of spinal anesthesia with hyperbaric bupivacaine regardless of patient position when the spinal injection is made. CSF volume influenced the duration of spinal sensory anesthesia when the injection was made with the patient in a seated position, but not in the lateral position.ImplicationsPatient position during the spinal injection does not alter the influence of cerebrospinal fluid (CSF) volume on the spread of hyperbaric bupivacaine spinal anesthesia. However, CSF volume influences the duration of spinal sensory anesthesia when the injection is made with the patient in a seated position, but not in the lateral position.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.