You need to sign in or sign up before continuing.


  • Acta Anaesthesiol Scand · Aug 1979

    Experimental studies on artificial ventilation using a tidal volume ventilator. Mechanics and dynamics of ventilation.

    • S Lindahl and L Okmian.
    • Acta Anaesthesiol Scand. 1979 Aug 1;23(4):359-69.

    AbstractIn 24 piglets (2.7-24.5 kg b.w.), the mechanics of ventilation, the accuracy of dosage of respiratory volumes, and the influence of the ventilator's volume/pressure characteristics (Cvent, "internal compliance") on the dynamic course of insufflation were studied. A linear relationship was shown to exist between tidal volume and end-inspiratory tracheal pressure and between tidal volume and insufflation time. The insufflation time was reduced to about 50% of previously registered values. The error between set and registered tidal volume was found to be 6.0 +/- 2.7%. During the insufflation a linear relationship was found between the instant amount of delivered breathing gas and the corresponding endotracheal pressure change. The ventilator's Cvent did (and body size, total compliance and tidal volume did not) significantly influence the size of the direction coefficient for the linear instantaneous volume/pressure relationship, the magnitude of tracheal peak pressure and a short insufflation time, and vice versa. The use of greater power from the ventilator resulted in a significant shortening of the duration of insufflation and vice versa. The duration of insufflation is the parameter of choice in evaluating the efficiency of the ventilatory equipment. When the ventilator's performance is defined, measurements of the duration of insufflation may enable evaluation of conditions within the lungs.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…