-
Randomized Controlled Trial
CPREzy improves performance of external chest compressions in simulated cardiac arrest.
- Stefan K Beckers, Max H Skorning, Michael Fries, Johannes Bickenbach, Stephan Beuerlein, Matthias Derwall, Ralf Kuhlen, and Rolf Rossaint.
- Department of Aneasthesiology, University Hospital Aachen, Rheinisch-Westfälische Technische Hochschule (RWTH) Aachen University, Germany. sbeckers@ukaachen.de
- Resuscitation. 2007 Jan 1; 72 (1): 100-7.
Aim Of The StudyExternal chest compression (ECC) is an essential part of cardiopulmonary resuscitation and usually performed without any adjuncts. Although different supportive devices have been developed, none have yet been implemented as a standard procedure to guide rescuers in resuscitation. This study investigates the effects of the CPREzy-pad on ECC performed by first year medical students during simulated cardiac arrest.Materials And MethodsTwo hundred and two subjects were randomised and asked to perform 5 min of single-rescuer-CPR. Group 1 (n = 111) was taught classic ECC, followed by ECC with the CPREzy and was tested in ECC with the CPREzy. Group 2 (n = 91) was taught and tested in classic ECC only. One week later each group was divided: Group 1A was tested in ECC with the CPREzy again; Group 1B was tested in classic ECC. Group 2A was taught and tested in ECC with CPREzy; Group 2B was tested in classic ECC again. Primary endpoints were compression rate (90-110/min) and compression depth (40-50mm).ResultsComparing groups 1 and 2, ECC was significantly superior with CPREzy (correct rate: 93.7% versus 19.8%, p < or = 0.01; depth: 71.2% versus 34.1%, p < or = 0.01). The group tested with CPREzy initially 1 week later (2A; n = 36) improved significantly in correct compression rate (19.8% versus 88.9%, p < or = 0.01) and compression depth (34.1% versus 75.0%, p < or = 0.02). The control-group (2B; n = 55) without CPREzy demonstrated poor performance in both evaluations (correct rate: 19.8% versus 25.5%, depth: 34.1% versus 43.6%).ConclusionCPREzy as a simple portable and re-usable device is able to improve performance of ECC in simulated cardiac arrest.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.