-
J Cardiovasc Med (Hagerstown) · Mar 2011
Randomized Controlled Trial Comparative StudyAnatomical extent of pulmonary vein isolation after cryoballoon ablation for atrial fibrillation: comparison between the 23 and 28 mm balloons.
- Gian B Chierchia, Carlo de Asmundis, Antonio Sorgente, Gaetano Paparella, Andrea Sarkozy, Stephan-Andreas Müller-Burri, Lucio Capulzini, Yoshinao Yazaki, and Pedro Brugada.
- Heart Rhythm Management Center, Cardiovascular Division, UZ Brussel-Vrije Universiteit Brussel, Brussels, Belgium. jeanbaptiste.chierchia@uzbrussel.be
- J Cardiovasc Med (Hagerstown). 2011 Mar 1;12(3):162-6.
BackgroundPulmonary vein isolation seems to occur in the distal part of the ostium leaving the atrium largely unablated when using the 23 mm cryoballoon catheter ablation for atrial fibrillation. We hypothesize that ablating with the larger 28 mm cryoballoon would target a wider portion of the left atrial cavity.AimTo compare the anatomical extent of pulmonary vein isolation using electroanatomical mapping when performing atrial fibrillation ablation with a 23 mm or a 28 mm cryoballoon.MethodsEight consecutive patients selected for circumferential pulmonary vein cryoballoon isolation for highly symptomatic paroxysmal atrial fibrillation were randomly assigned to ablation with the 23 or 28 mm balloon. After ablation, electroanatomical mapping was performed to compare the anatomical extent of pulmonary vein isolation between the two balloon dimensions.ResultsExtent of pulmonary vein isolation significantly differed when the lesions with either balloon dimensions were compared. Pulmonary vein isolation only occurred in the tubular part of the ostium when performed with the 23 mm balloon. Conversely, the lesion created with the 28 mm balloon included a larger portion of the left atrium. In fact, when using the smaller balloon (23 mm) the mean documented extent of electrical isolation was 20.7 ± 2.8% of the maps' surface, whereas it was 40.2 ± 3.9% when performing ablation with the bigger balloon (28 mm). The difference in calculated area of electrical isolation between group A and B was statistically significant (P < 0.05).ConclusionPulmonary vein isolation occurs significantly more proximally in the atrium when performing atrial fibrillation ablation with a 28 mm cryoballoon when compared with a 23 mm balloon.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.