Multicenter Study
Rate, causes, and impact on patient outcome of implantable device complications requiring surgical revision: large population survey from two centres in Italy.
- Pietro Palmisano, Michele Accogli, Maria Zaccaria, Giovanni Luzzi, Frida Nacci, Matteo Anaclerio, and Stefano Favale.
- Cardiology Unit, 'Card. G. Panico' Hospital, Tricase (Le), Italy. dr.palmisano@libero.it
- Europace. 2013 Apr 1;15(4):531-40.
AimsThe long-term impact of implantable device-related complications on the patient outcome has not been thoroughly evaluated. The aims of this retrospective, bi-centre study were to analyse the rate and nature of device-related complications requiring surgical revision in a large series of patients undergoing device implantation, elective generator replacement and pacing system upgrade and to systematically assess the impact of such complications on patient outcome and healthcare utilization.Methods And ResultsData from 2671 consecutive procedures (1511 device implantations, 1034 elective generator replacements, and 126 pacing system upgrades) performed between January 2006 and March 2011 were retrospectively analysed. The outcome measures recorded were complication-related mortality, number of re-operations, need for complex surgical procedures, number of re-hospitalizations, and additional hospital treatment days. Over a median follow-up of 27 months, the overall rate of complications was 2.8% per procedure-year [9.5% in cardiac resynchronisation therapy (CRT) device implantation, 6.1% in pacing system upgrade, 3.5% in implantable cardioverter defibrillator implantation, 1.7% in pacemaker implantation, and 1.7% in generator replacement). The procedure with the highest risk of complications was CRT device implantation (odds ratio: 6.6; P < 0.001); these complications primarily involved coronary sinus lead dislodgement and device infection. Patients with complications had a significantly higher number of device-related hospitalizations (2.3 ± 0.6 vs. 1.0 ± 0.1; P < 0.001) and hospital treatment days (15.7 ± 25.1 vs. 3.6 ± 1.1; P < 0.001) than those without complications. Device infection was the complication with the greatest negative impact on patient outcome.ConclusionCardiac resynchronisation therapy implantation was the procedure with the highest risk of complications requiring surgical revision. Complications were associated with substantial clinical consequences and a significant increase in the number and length of hospitalizations.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.