• Heart Lung · Mar 1976

    Effect of airway diameter, suction catheters, and the bronchofiberscope on airflow in endotracheal and tracheostomy tubes.

    • H Baier, R Begin, and M A Sackner.
    • Heart Lung. 1976 Mar 1;5(2):235-8.

    AbstractPressure-flow relationships of an artificial airway-mechanical ventilator system were investigated. Endotracheal tubes varying from 7 to 9.5 mm. internal diameter and tracheostomy tubes from 7 to 10 mm. internal diameter were tested over flow-rates from 0.3 to 1.4 L. per second using a tidal volume of 500 ml. The effect of partial obstruction within these airways by suction catheters and the bronchofiberscope was examined. Depending on the internal diameter and the flow-rate, the driving pressure necessary to overcome the resistance of the tubes ranged from 5 to 20 cm. H2O. Partial obstruction of the artificial airways by suction catheters further increased this pressure. The introduction of the bronchofiberscope through an endotracheal tube of 7.5 mm. internal diameter, leaving an effective diameter of 4.9 mm., produced a driving pressure as high as 70 cm. H2O and reduced the flow rate to 50 per cent and the tidal volume to 80 per cent of its set value. Attention should be paid to duration of tracheobronchial suction while the patient is removed from the respirator since a high-grade resistance is created by passage of a suction catheter through an endotracheal tube. Bronchofiberscopy should be cautiously performed through cuffed artificial airways with at least 8 mm. internal diameter because the airway may be too comprised even if mechanical ventilatory assistance is employed.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.