• Anesthesia and analgesia · Dec 2012

    Randomized Controlled Trial

    Reduction in intraoperative bacterial contamination of peripheral intravenous tubing through the use of a passive catheter care system.

    • Randy W Loftus, Bryan S Brindeiro, David P Kispert, Hetal M Patel, Matthew D Koff, Jens T Jensen, Thomas M Dodds, Mark P Yeager, Kathryn L Ruoff, John D Gallagher, Michael L Beach, and Jeremiah R Brown.
    • Department of Anesthesiology, Dartmouth-Hitchcock Medical Center, 1 Medical Center Dr., Lebanon, NH 03756, USA. randy.w.loftus@hitchcock.org
    • Anesth. Analg.. 2012 Dec 1;115(6):1315-23.

    BackgroundBacterial contamination of intravascular devices has been associated with increased morbidity and mortality in various hospital settings, including the perioperative environment. Catheter hub disinfection has been shown in an ex vivo model to attenuate intraoperative injection of bacterial organisms originating from the anesthesia provider's hands, providing the impetus for improvement in intraoperative disinfection techniques and compliance. In the current study, we investigated the clinical effectiveness of a new, passive catheter care station in reducing the incidence of bacterial contamination of open lumen patient IV stopcock sets. The secondary aim was to evaluate the impact of this novel intervention on the combined incidence of 30-day postoperative infections and IV catheter-associated phlebitis.MethodsFive hundred ninety-four operating room environments were randomized by a computer-generated list to receive either a novel catheter care bundle (HubScrub and DOCit) or standard caps in conjunction with a sterile, conventional open lumen 3-way stopcock set (24 inch with 3-gang 4-way and T-Connector). Patients underwent general anesthesia according to usual practice and were followed prospectively for 30 postoperative days to identify the development of health care-associated infections (HCAIs) and/or phlebitis. The primary outcome was intraoperative bacterial contamination of the primary stopcock set used by the anesthesia provider(s). The secondary outcome was the combined incidence of 30-day postoperative infections and phlebitis.ResultsFive hundred seventy-two operating rooms were included in the final analysis. Study groups were comparable with no significant differences in patient, provider, anesthetic, or procedural characteristics. The catheter care station reduced the incidence of primary stopcock lumen contamination compared with standard caps (odds ratio [OR] 0.79, 95% confidence interval [CI] 0.63-0.98, P = 0.034) and was associated with a reduction in the combined incidence of HCAIs and IV catheter-associated phlebitis with and without adjustment for patient and procedural covariates (OR(adjusted) 0.589, 95% CI 0.353-0.984, P = 0.040). The risk-adjusted number needed to treat to eliminate 1 case of lumen contamination was 9 (95% CI 3.4-13.5) patients, whereas the risk-adjusted number needed to treat to eliminate 1 case of HCAI/catheter-associated phlebitis was 17 (95% CI 11.8-17.9) patients.ConclusionIntraoperative use of a passive catheter care station significantly reduced open lumen bacterial contamination and the combined incidence of 30-day postoperative infections and phlebitis.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…