    A comparison of vital signs charted by nurses with automated acquired values using waveform quality indices.

    • Monica Sapo, Shaozhi Wu, Shadnaz Asgari, Norma McNair, Farzad Buxey, Neil Martin, and Xiao Hu.
    • Department of Neurosurgery, University of California, Los Angeles, 90095, USA.
    • J Clin Monit Comput. 2009 Oct 1;23(5):263-71.

    Objective(1) To investigate if there exist any discrepancies between the values of vital signs charted by nurses and those recorded by bedside monitors for a group of patients admitted for neurocritical care. (2) To investigate possible interpretations of discrepancies by exploring information in the alarm messages and the raw waveform data from monitors.MethodsEach charted vital sign value was paired with a corresponding value from data collected by an archival program of bedside monitors such that the automatically archived data preceded the charted data and had minimal time lag to the charted value. Next, the absolute differences between the paired values were taken as the discrepancy between charted and automatically-collected data. Archived alarm messages were searched for technical alarms of sensor/lead failure types. Additionally, 7-min waveform data around the place of large discrepancy were analyzed using signal abnormality indices (SAI) for quantifying the quality of recorded signals.ResultsAbout 31,145 pairs of systolic blood pressure (BP-S) and 67,097 pairs of SpO(2) were investigated. Seven and a half percent of systolic blood pressure pairs had a discrepancy greater than 20 mmHg and less than one percent of the SpO2 pairs had a discrepancy greater than 10. We could not find any technical alarms from the monitors that could explain the large difference. However, SAI calculated for the waveforms associated with this group of cases was significantly larger than the SAI values calculated for the control waveform data of the same patients with small discrepancies.ConclusionCharted vital signs reflect in large the raw data as reported by bedside monitors. Poor signal quality could partially explain the existence of cases of large discrepancies.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.