Arch. Otolaryngol. Head Neck Surg. · Feb 2011
Navigated surgery at the lateral skull base and registration and preoperative imagery: experimental results.
- Florian Kral, Herbert Riechelmann, and Wolfgang Freysinger.
- Department of Otorhinolaryngology, Innsbruck Medical University, Anichstr 35, 6020 Innsbruck, Austria. florian.kral@i-med.ac.at
- Arch. Otolaryngol. Head Neck Surg. 2011 Feb 1;137(2):144-50.
ObjectivesTo assess factors that affect the accuracy of navigated surgery at the human lateral skull base, including the choice of registration procedures and preoperative computed tomography (CT) section thickness, and to compare target registration error, a measure of clinical application accuracy, with root mean square, an accuracy variable provided by several surgical navigation systems.DesignExperimental cadaver study.SettingMedical university.ParticipantsAnatomic specimen.Main Outcome MeasuresTarget registration error.ResultsA combination of high-resolution CT images, 0.5-mm section thickness, with pair-point matching of a combination of markers on the anatomical specimen, and the registration element was found to be superior (mean [SD], 0.72 [0.28] mm). No correlation was found between target registration error and root mean square. A statistical analysis that considers image registration and acquisition method did not show any correlation between target registration error and root mean square error (r = -0.175, P = .15).ConclusionsHigh-resolution CT images, 0.5 mm, of the petrous bone and a pair-point registration using loci on the patient and registration superstructures worked best under experimental conditions. Only target registration error was found to provide reliable information on accuracy intraoperatively. In line with the literature, these data prove that root mean square bears little relevance for clinical application accuracy.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.