• Sleep Breath · Nov 2009

    Accuracy of autotitrating CPAP to estimate the residual Apnea-Hypopnea Index in patients with obstructive sleep apnea on treatment with autotitrating CPAP.

    • Himanshu Desai, Anil Patel, Pinal Patel, Brydon J B Grant, and M Jeffery Mador.
    • State University of New York at Buffalo, USA.
    • Sleep Breath. 2009 Nov 1;13(4):383-90.

    ObjectiveAutotitrating continuous positive airway pressure (auto-CPAP) devices now have a smart card (a pocket-sized card with embedded integrated circuits which records data from the CPAP machine such as CPAP usage, CPAP pressure, large leak, etc.) which can estimate the Apnea-Hypopnea Index (AHI) on therapy. The aim of this study was to determine the accuracy of auto-CPAP in estimating the residual AHI in patients with obstructive sleep apnea (OSA) who were treated with auto-CPAP without a CPAP titration study.Patients And MethodsWe studied 99 patients with OSA from April 2005 to May 2007 who underwent a repeat sleep study using auto-CPAP. The estimated AHI from auto-CPAP was compared with the AHI from an overnight polysomnogram (PSG) on auto-CPAP using Bland-Altman plot and likelihood ratio analyses. A PSG AHI cutoff of five events per hour was used to differentiate patients optimally treated with auto-CPAP from those with residual OSA on therapy.ResultsBland and Altman analysis showed good agreement between auto-CPAP AHI and PSG AHI. There was no significant bias when smart card estimates of AHI at home were compared to smart card estimates obtained in the sleep laboratory. An auto-CPAP cutoff for the AHI of six events per hour was shown to be optimal for differentiating patients with and without residual OSA with a sensitivity of 0.92 (95% confidence interval (CI) 0.76 to 0.98) and specificity of 0.90 (95% CI 0.82 to 0.95) with a positive likelihood ratio (LR) of 9.6 (95% CI 5.1 to 21.5) and a negative likelihood ratio of 0.085 (95% CI 0.02 to 0.25). Auto-CPAP AHI of eight events per hour yielded the optimal sensitivity (0.94, 95% CI 0.73 to 0.99) and specificity (0.90, 95% CI 0.82 to 0.95) with a positive LR of 9.6 (95% CI 5.23 to 20.31) and a negative LR of 0.065 (95% CI 0.004 to 0.279) to identify patients with a PSG AHI of > or = 10 events per hour.ConclusionAuto-CPAP estimate of AHI may be used to estimate residual AHI in patients with OSA of varying severity treated with auto-CPAP.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…