Scand J Trauma Resus · Jan 2013
The intrapleural volume threshold for ultrasound detection of pneumothoraces: an experimental study on porcine models.
- Nils Petter Oveland, Eldar Søreide, Hans Morten Lossius, Frode Johannessen, Kristian Borup Wemmelund, Rasmus Aagaard, and Erik Sloth.
- Department of Research and Development, Norwegian Air Ambulance Foundation, Mailbox 94, Droebak, 1441, Norway. nils.petter.oveland@norskluftambulanse.no
- Scand J Trauma Resus. 2013 Jan 1;21:11.
BackgroundSmall pneumothoraxes (PTXs) may not impart an immediate threat to trauma patients after chest injuries. However, the amount of pleural air may increase and become a concern for patients who require positive pressure ventilation or air ambulance transport. Lung ultrasonography (US) is a reliable tool in finding intrapleural air, but the performance characteristics regarding the detection of small PTXs need to be defined. The study aimed to define the volume threshold of intrapleural air when PTXs are accurately diagnosed with US and compare this volume with that for chest x-ray (CXR).MethodsAir was insufflated into a unilateral pleural catheter in seven incremental steps (10, 25, 50, 100, 200, 350 and 500 mL) in 20 intubated porcine models, followed by a diagnostic evaluation with US and a supine anteroposterior CXR. The sonographers continued the US scanning until the PTXs could be ruled in, based on the pathognomonic US "lung point" sign. The corresponding threshold volume was noted. A senior radiologist interpreted the CXR images.ResultsThe mean threshold volume to confirm the diagnosis of PTX using US was 18 mL (standard deviation of 13 mL). Sixty-five percent of the PTXs were already diagnosed at 10 mL of intrapleural air; 25%, at 25 mL; and the last 10%, at 50 mL. At an air volume of 50 mL, the radiologist only identified four out of 20 PTXs in the CXR pictures; i.e., a sensitivity of 20% (95% CI: 7%, 44%). The sensitivity of CXR increased as a function of volume but leveled off at 67%, leaving one-third (1/3) of the PTXs unidentified after 500 mL of insufflated air.ConclusionLung US is very accurate in diagnosing even small amounts of intrapleural air and should be performed by clinicians treating chest trauma patients when PTX is among the differential diagnoses.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.