• J. Vasc. Surg. · Apr 1997

    Comparative Study

    Continuous electroencephalographic monitoring and selective shunting reduces neurologic morbidity rates in carotid endarterectomy.

    • K A Plestis, P Loubser, E M Mizrahi, G Kantis, Z D Jiang, and J F Howell.
    • Department of Vascular Surgery, Baylor College of Medicine, Houston, TX, USA.
    • J. Vasc. Surg. 1997 Apr 1;25(4):620-8.

    PurposeThe role of continuous electroencephalographic (EEG) monitoring during carotid endarterectomy was evaluated in this retrospective review.MethodsWe analyzed data from 902 consecutive carotid endarterectomy procedures performed with vein patch angioplasty. In 591 operations from 1980 to 1988 we did not use intraoperative EEG monitoring or shunting (non-EEG group). Continuous intraoperative EEG monitoring and selective shunting were used in 311 procedures from 1988 to 1994 (EEG group). The patients' mean age was higher in the EEG group (68.8 years; range, 41 to 87 years) than in the non-EEG group (66.2 years; range, 34 to 90 years; p < 0.001). There was also a significantly higher incidence of hypertension (56.2% vs 41.9%) and redo operations (5.4% vs 2.54%) in the EEG group than in the non-EEG group (p < 0.05). The operative technique was identical in both groups. We defined a significant EEG change as a greater than 50% reduction of the amplitude of the faster frequencies, a persistent increase of delta activity, or both.ResultsIn the EEG group, acute EEG changes occurred in 40 patients (12.8%); 31 (77.5%) unilateral and ipsilateral to the operated carotid artery, and nine (22.5%) bilateral. In five patients (12.5%) the changes correlated with an intraoperative episode of hypotension, and after normal blood pressure was restored the EEG returned to normal. In 35 procedures (87.5%) a carotid shunt was inserted. In 33 of those patients the EEG returned to baseline, in one patient there was a significant improvement, and in one patient the EEG changes persisted. Postoperative hospital strokes occurred in one patient (0.32%) in the EEG group and in 13 patients (2.19%) in the non-EEG group (p < 0.05). All strokes (n = 14) were ipsilateral to the operated carotid artery. Of the 13 strokes in the non-EEG group nine were major and four were minor. The one stroke in the EEG group was embolic in origin and occurred before carotid cross-clamping; it was associated with profound EEG changes that did not reverse after placement of a shunt. In the total group (n = 902), intraoperative EEG monitoring was inversely associated with postoperative stroke (p < 0.05).ConclusionThe overall neurologic morbidity rate was significantly lower in the EEG group than in the non-EEG group, therapy demonstrating the value of intraoperative EEG monitoring in carotid endarterectomy.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…