• J Orthop Trauma · Sep 2009

    Comparative Study

    Locking reconstruction double plating of distal humeral fractures: how many screws in the distal ulnar column segment in A3 fracture provide superior stability? A comparative biomechanical in vitro study.

    • Isabella Mehling, Kay Schmidt-Horlohé, Lars Peter Müller, Werner Sternstein, Jan Korner, and Pol Maria Rommens.
    • Department of Trauma Surgery, University Hospital of the Johannes Gutenberg University, Langenbeckstrasse 1, 55101 Mainz, Germany. mehling@unfall.klinik.uni-mainz.de
    • J Orthop Trauma. 2009 Sep 1;23(8):581-7.

    ObjectivesTwo 90-degree configurations of locking reconstruction plates with different numbers of screws in the distal ulnar column segment of distal extra-articular humeral fractures with metaphyseal comminution (A3) were biomechanically investigated.MethodsEight pairs of fresh-frozen human humeri were used. For paired comparison, the humeri were divided into 2 randomized groups. In both groups, double-plate osteosyntheses with locking reconstruction plates were performed in 90-degree configurations. In group 1, the posteriorly placed radial column plate exceeded the capitellum and the ulnar column plate extended into the ulnar sulcus. The ulnar plate was molded around the medial epicondyle and fixed with 3 short angular stable screws distally. In group 2, the posteriorly placed radial column plate was applied analogous to group 1. The locking reconstruction plate placed on the ulnar column was used reaching to the ulnar epicondyle, fixed with 1 long, angular, stable screw in the distal fragment. Stiffness testing for axial load and bending in static and cyclic tests were performed. In static test mode, a load was applied with a frequency of 0.1 Hz. For cyclic loading conditions, a load was applied at 1 Hz for 5000 cycles.ResultsAll tested specimens adequately resisted simulated physiologic loading conditions with no failure. Comparable stiffness values for axial load (P = 0.161) and significant lower stiffness values for bending (P = 0.017) in group 2 under static bending conditions were found. Considering cyclic loading conditions, no significant alterations in stiffness in each group under axial load occurred. In bending conditions, stiffness values for group 2 were significantly lower than that for group 1 (P = 0.036).ConclusionsUnder static and cyclic bending conditions, stiffness in group 2 was significantly lower than that in group 1. Nevertheless, both implant configurations showed no failure of the constructs. Based on these data, when applying locked plates in the clinical setting, more than 1 locked screw applied into the distal ulnar column of the articular segment is recommended.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.