• Anesthesia and analgesia · Jan 2013

    Randomized Controlled Trial Comparative Study

    A prospective randomized trial of lidocaine 30 mg versus 45 mg for epidural test dose for intrathecal injection in the obstetric population.

    • Stephen Pratt, Anasuya Vasudevan, and Philip Hess.
    • Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215, USA. spratt@bidmc.harvard.edu
    • Anesth. Analg.. 2013 Jan 1;116(1):125-32.

    BackgroundThe epidural test dose, used to identify unintended intrathecal placement, should reliably produce a spinal block without posing a threat to the patient. Most anesthesiologists administer a dose of local anesthetic, commonly lidocaine 45 mg. Pregnant patients are more sensitive to local anesthetics; high and total spinal anesthesia have been reported in the pregnant population with this dose. We hypothesized that lidocaine 30 mg was as effective as lidocaine 45 mg in creating rapid objective evidence of a sensory or motor block.MethodsIn this prospective, randomized, double-blind trial, patients scheduled for cesarean delivery were assigned to 1 of 4 groups: lidocaine 30 mg in the spinal or epidural space, or lidocaine 45 mg by the same routes. A blinded observer assessed the degree of sensory and motor block. The ability to identify intrathecal injection of each dose was compared. Sensory block above T6 dermatome and hypotension were recorded as side effects.ResultsIntrathecal administration of lidocaine 30 mg produced rapid subjective and objective signs of neuroblockade within 3 minutes (100%, 95% confidence interval CI, 85%-100% for each). Lidocaine 45 mg produced similar results. All patients in both groups described their legs as warm or heavy after 3 minutes and had a motor block by 5 minutes. On the basis of an intrathecal catheter rate of 1:380, the observed negative predictive value for intrathecal placement if the patient described no sensory changes at 3 minutes was 100% (95% CI, 99.95%-100%) for 30 mg and 100% (95% CI, 99.93%-100%) for 45 mg. We did not identify a decrease in the rate of side effects with the lower dose.ConclusionsOur results suggest that there is unlikely to be a large difference in the ability of these doses to detect unintentional intrathecal catheter placement. While the negative predictive value for intrathecal injection is very high for both doses, the 95% CI for the sensitivity of either dose is too wide to demonstrate clinical safety to identify all intrathecal catheters. A much larger study is warranted to assess whether there is a lower sensitivity with the 30-mg dose, or a propensity toward high cephalad motor block levels with the 45-mg dose.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    This article appears in the collection: Regional stuff.

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.