Bmc Med Inform Decis · Jan 2012
Comparative StudyComparison of alphabetical versus categorical display format for medication order entry in a simulated touch screen anesthesia information management system: an experiment in clinician-computer interaction in anesthesia.
- Anil A Marian, Franklin Dexter, Peter Tucker, and Michael M Todd.
- Department of Anesthesia, University of Iowa, Iowa City, IA 52242, USA. anil-marian@uiowa.edu
- Bmc Med Inform Decis. 2012 Jan 1;12:46.
BackgroundAnesthesia information management system (AIMS) records should be designed and configured to facilitate the accurate and prompt recording of multiple drugs administered coincidentally or in rapid succession.MethodsWe proposed two touch-screen display formats for use with our department's new EPIC touch-screen AIMS. In one format, medication "buttons" were arranged in alphabetical order (i.e. A-C, D-H etc.). In the other, buttons were arranged in categories (Common, Fluids, Cardiovascular, Coagulation etc.). Both formats were modeled on an iPad screen to resemble the AIMS interface. Anesthesia residents, anesthesiologists, and Certified Registered Nurse Anesthetists (n = 60) were then asked to find and touch the correct buttons for a series of medications whose names were displayed to the side of the entry screen. The number of entries made within 2 minutes was recorded. This was done 3 times for each format, with the 1st format chosen randomly. Data were analyzed from the third trials with each format to minimize differences in learning.ResultsThe categorical format had a mean of 5.6 more drugs entered using the categorical method in two minutes than the alphabetical format (95% confidence interval [CI] 4.5 to 6.8, P < 0.0001). The findings were the same regardless of the order of testing (i.e. alphabetical-categorical vs. categorical - alphabetical) and participants' years of clinical experience. Most anesthesia providers made no (0) errors for most trials (N = 96/120 trials, lower 95% limit 73%, P < 0.0001). There was no difference in error rates between the two formats (P = 0.53).ConclusionsThe use of touch-screen user interfaces in healthcare is increasingly common. Arrangement of drugs names in a categorical display format in the medication order-entry touch screen of an AIMS can result in faster data entry compared to an alphabetical arrangement of drugs. Results of this quality improvement project were used in our department's design of our final intraoperative electronic anesthesia record. This testing approach using cognitive and usability engineering methods can be used to objectively design and evaluate many aspects of the clinician-computer interaction in electronic health records.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.