-
Comparative Study Observational Study
Clinical effectiveness of cardiac resynchronization and implantable cardioverter-defibrillator therapy in men and women with heart failure: findings from IMPROVE HF.
- Jane E Wilcox, Gregg C Fonarow, Yan Zhang, Nancy M Albert, Anne B Curtis, Mihai Gheorghiade, J Thomas Heywood, Mandeep R Mehra, Christopher M O'Connor, Dwight Reynolds, Mary Norine Walsh, and Clyde W Yancy.
- Division of Cardiology.
- Circ Heart Fail. 2014 Jan 1;7(1):146-53.
BackgroundMany clinical trials have demonstrated a benefit for cardiac resynchronization (CRT) and implantable cardioverter-defibrillator (ICD) therapies in patients with heart failure and reduced ejection fraction, yet questions have been raised with regard to the benefit of ICDs for women. The purpose of this study was to determine the clinical effectiveness of CRT and ICD therapy as a function of sex in outpatients with heart failure and reduced ejection fraction (≤35%).Methods And ResultsData from the Registry to Improve the Use of Evidence-Based Heart Failure Therapies in the Outpatient Setting (IMPROVE HF) were analyzed by device status and sex among guideline-eligible patients for vital status (alive/dead) at 24 months. Multivariate generalized estimating equation analyses were conducted adjusting for baseline patient and practice characteristics. In the ICD/CRT-defibrillator (CRT-D) eligible cohort (n=7748), there were 5485 (71%) men and 2261 (29%) women. In the CRT-pacemaker (CRT-P)/CRT-D eligible cohort (n=1188), there were 824 (69%) men and 364 (31%) women. The clinical benefit associated with ICD/CRT-D therapy was similar in both men and women (men adjusted odds ratio, 0.71; 95% confidence interval, 0.57-0.87; P=0.0012; and women adjusted odds ratio, 0.65; 95% confidence interval, 0.49-0.85; P=0.0019). For CRT-P/CRT-D, the associated benefits showed no significant heterogeneity (men adjusted odds ratio, 0.59; 95% confidence interval, 0.33-1.06; P=0.0793; and women adjusted odds ratio, 0.44; 95% confidence interval, 0.22-0.90; P=0.0243). The device-by-sex interactions were not significant (P=0.4441 for CRT-P/CRT-D and P=0.5966 for ICD/CRT-D).ConclusionsThe use of guideline-directed CRT and ICD therapy was associated with substantially reduced 24-month mortality in eligible men and women with heart failure and reduced ejection fraction. Device therapies should be offered to all eligible patients with heart failure, without modification based on sex.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.